Flintec II PC-BASED User Manual
Page 31

FlintWeigh Technical Manual, Rev. 3.03 November 2011
Page 31 of 32
Function
Description
Status(w)
Read scale status
Parameter
Type
Use
w
Integer
w = 1 (scale 1); w = 2 (scale 2); w = 3 (dual scale)
Return value
Value range
Format: string, 31 digits:
"AB_gggggggdd_tttttttdd_nnnnnndd" with
A
Status bit 1
2
0
(= 1) = No motion
2
1
(= 2) = Active tare (net indication)
2
2
(= 4) = Zero setting range
2
3
(= 8) = Accurate zero
2
4
(= 16) = Error
B
Status bit 2
2
0
(= 1) = Zero crossing
2
1
(= 2) = Minimum load
2
2
(= 4) = Tilt switch
gggggggdd
Gros value and unit
0...800 000 / g, kg, t, lb
tttttttdd
Tare value and unit
0...800 000 / g, kg, t, lb
nnnnnnndd
Net value and unit
0...800 000 / g, kg, t, lb
Hint: Unused places within the weight value will be filled with spaces.
SetOutput(o,w,f,v) Configure digital outputs and setpoints
Parameter
Type
Use
o
32-bit Integer
o = 1 (output 1); o = 2 (output 2)
w
32-bit Integer
w = 1 (scale 1); w = 2 (scale 2); w = 3 (dual scale)
f
32-bit Integer
Flag
Operation
2
0
2
1
00
Output not used
01
Fixed setting
02
Setpoint control
03
Traffic control
2
2
0 (= 0) Under-run
1 (= 1) Exceeded
2
3
0 (= 0) Gros value
1 (= 8) Net value
2
4
Status of fixed setting
0 (= 0) Off
1 (= 16) On
2
5
Enabled by input
0 (= 0) Off
1 (= 32) On
v
32-bit Integer
Setpoint including all decimal places but without decimal
point ( e.g. 13.25 kg
v = 1325)
All functions are characterised in the type library “NW10.TLB”, which may be included into the programming
environment of the application programme.