FlintWeigh II Configuration
7.1. Basic Setup during the Commissioning
When you commission FlintWeigh II for the first time, following basic setup has to be done:
•
Sensor interface and Sensor type (
standard load cells OR digital load cells)
•
Scale system
•
Data memory
•
Interface to remote display and remote display type
•
Gravitational factor, if applicable
These basic settings will be described in this chapter.
Fig. 8.1 Weight display before commissioning
Start the main programme ”NW11F.EXE“
A click on this button will open the service functions
(window FlintWeigh II Settings).
Fig.8.2 Register „Communication“
Sensor interface:
Select the serial interface, which has been assigned to the weighing system
controller (see chapter 5.3) and set up the baud rate to „9600“
Sensor type:
Defines, if standar or digital load cells will be connected
(LDU = standard load cells; RC3D,= digital load cells)
Scale system:
Defines, if there will be “1 scale“, “2 scales“ (independend from each other) or a
“Dual scale”
(Dual scale = sum of scale no.1 and scale no.2)
Data memory:
Location for the alibi memory (see chapter 8.1.1)
Remote display:
Define interface and type as required
Gravitational factor:
Is only used, if the calibration location and the installation location are not
identical. Otherwise this parameter remains untouched.
Default setting: 9.8075656