Analogue set value input "S1" (Pink)
Via this input, using a set value in the range from 0-10 VDC, any speed set

value in the range from 0 to n

max

. can be specified in rpm. Blank (set value

voltage = 0 VDC), the motor remains at a standstill and attempts to control

the motor at maximum torque (holding torque) when there is an attempt to

move the drive. In the standard designs, n

max

. is defined as 4000 rpm. For

different design variants, refer to the respective product specifications for the

value for n

max

.

NOTE
For drives in the design with input "S1" (analogue set
value), the frequency set value input is not defined.
Æ

Do not connect input "F+".

Operating voltage range

V

0 to 10

For cable break

-

Level "0"

Internal resistance

kΩ 30

Set value range

-

50 mV to 9.9 V correspond to

0 to n

max

. in rpm

Signal resolution

bit

10

Protection against reverse

polarity and voltage

V

≤ 30

Fig.6 Internal input wiring of set value input S1

Fig.7 Characteristics of set value input S1 for speed setting via analogue

voltage

Analogue set value input "S2" (brown)
Via this input, with a set value in the range of 0-5 VDC, the current limit can

be specified in the range from 0 (no torque, motor does not move, rotor runs

freely) to 100 % (maximum torque). Therefore, input "S2" must be connected

in order to operate the drive. The current limit configured via input "S2" works

equally for driving and for braking.

Operating voltage range

V

0 to 5

For cable break

-

Level "0"

Internal resistance

kΩ 30

Set value input range

-

0 to 5 V correspond to 0 to 100 %

(max. torque)

Signal resolution

bit

9

Protection against reverse

polarity and voltage

V

≤ 30

GND

S2

Fig.8 Internal input wiring of set value input S2

Fig.9 Characteristics of set value input S2 for torque specification via

analogue voltage

Frequency set value input "F+" (red-blue)
This input is available for drive versions with frequency set value only and is
used to specify a speed set value using a defined frequency signal. For
detailed information in this regard, refer to the product specification.

NOTE
For drives in the design with frequency set value input, the
input "S1" (analogue set value) is not defined.
Æ

Do not connect input "S1".

RS-485 interface "Data A" and "Data B" (white / green)

NOTE
The RS-485 interface is not available in the basic variants.
The interface is used for adapting drive parameters or software
variants at the factory.
Æ

Do not connect the RS 485 interface.

GND