VDC-3-49.15

Assembly instructions

Article No.: 194 0005 008 · Version: V1.0 · dated 08.11.2011 · Page 5 of 14

ebm-papst St. Georgen GmbH & Co. KG · Hermann-Papst-Straße 1 · 78112 St. Georgen · Phone: +49 7724 81-0 · Fax: +49 7724 81-1309 · www.ebmpapst.com · [email protected]

Ori

g

inal installation

3.3 Technical description

Note: The performance data, dimensions and functions listed in these
assembly instructions apply for the corresponding standard designs of the
VDC-3-49.15 drive in 24 or 48 V with analogue set value input.
For deviating performance data, dimensions and/or functions, refer to the
corresponding product specifications and/or drawings of the corresponding
design variants.

3.4 Transport and storage conditions

Storage conditions EN 61800-1:1998

Climatic conditions EN 60721-3-1:1998
Ambient temperature

Class

°C

1K4

-25 to +55

Climatic conditions EN 60721-3-1:1998
Relative humidity

Class

%

1K3

5 to 95

Max. storage elevation

m above sea

level

3000

Transport conditions EN 61800-1:1998

Climatic conditions EN 60721-3-2:1998
Ambient temperature

Class

°C

2K3

-25 to +70

Climatic conditions EN 60721-3-2:1998
Relative humidity at +40 °C

Class

%

2K3

95

4 CONNECTION DESCRIPTION

4.1 Pin configuration

Designation

Colour

Description

Gnd

Blue (AWG 16)

Supply ground

U

B

Brown (AWG 16) Logic supply voltage

U

ZK

Black (AWG 16)

Supply voltage

A grey-pink

Digital

control

input

B violet Digital

control

input

C black Hardware

enable

D

yellow

Drive status: ready (yes/no)

E

red

Actual speed output, Channel A

F+ red-blue

Not assigned (optional for variant with
frequency set value)

IST

grey

Actual speed output, Channel B

S1

Pink

set value input

S2

brown

Adjustable current limit

Data A

white

RS485 (Data +)

Data B

green

RS485 (Data -)

Gnd Blue Logic

Ground

4.2 Specification of the interface

Digital control inputs "A" (grey-pink) and "B" (violet) - digital input
signals
Via the control signals at inputs "A" and "B", the various operating states can
be selected according to the logic below.

Input level

-

TTL level

Low level

V

< 0.8

High level

V

> 2.0

Protection against
reverse polarity and
voltage

V

≤ 30

For cable break

-

Logic level "0"

Internal resistance

kΩ 22

Applied logic level

-

A=0/B=0 = Power stage disabled
A=1/B=0 = Direction of rotation* cw
A=0/B=1 = Direction of rotation* ccw
A=1/B=1 = Brake

* View onto the motor shaft from the
front

A/B

GND

Fig.3 Internal input wiring of inputs A and B

Digital control input "C" (black) - hardware enable
The control input "C" is used for targeted switching on/off of the power stage

of the drive, independent of the supply voltage. In addition, this input is used

for switching on again (acknowledgement) after a fault shut-off (fault status

at digital output "D"). Switch-on/acknowledgement takes place with a change

of the signal level from 0 to 1.

Input level

-

TTL level

Low level

V

< 0.8

High level

V

> 2.0

Protection against

reverse polarity and

voltage

V

≤ 22

For cable break

-

Power stage "OFF"

Internal resistance

kΩ 8

Applied logic level

-

0 = Power stage switched off

1 = Power stage switched on