Reporting current or selected values, Reporting supported range of parameter values, A8i: - ci signal indication – Comtrol AT Commands User Manual
Page 105: Indication syntax, Defined values, Example

AT Commands for CX81801/CX06833/CX81300/CX06827 Modems Reference Manual
102184B
Conexant
3-79
Default values: 1,1,00,1,0,0
The ATD and ATA commands behave as specified in V.250, and +A8n indications are
not generated by the modem.
For subparameter values
the course of the V.8 session to notify the DTE when the relevant V.8 signals are
received.
Reporting Current or Selected Values
Command: +A8E?
Response: +A8E:
Example:
+A8E: 1,1,00,1,0,0
For the defaults
Reporting Supported Range of Parameter Values
Command: +A8E=?
Response: +A8E: (
(
Example: +A8E:
(1,6),(1,5),(0,21,C1),(0,1),(0),(0)
+A8I: - CI Signal Indication
This indication is issued by an answering modem, if +A8E,
≠ 0, to indicate
detection of a V.8 CI signal, and report the recovered Call Function octet(s).
Indication Syntax
+A8I:
Defined Values
A hexadecimal code octet representation of those Call
Function octet(s). +A8I:0 indicates that the modem timed out
waiting for CI.
Example
+A8I:0
The modem timed out waiting for CI.
+A8I:X YYY