beautypg.com

Reporting current or selected values, Reporting supported range of parameter values, A8i: - ci signal indication – Comtrol AT Commands User Manual

Page 105: Indication syntax, Defined values, Example

background image

AT Commands for CX81801/CX06833/CX81300/CX06827 Modems Reference Manual

102184B

Conexant

3-79

Default values: 1,1,00,1,0,0

The ATD and ATA commands behave as specified in V.250, and +A8n indications are
not generated by the modem.

For subparameter values =6 and =5, the +A8I indications are issued during
the course of the V.8 session to notify the DTE when the relevant V.8 signals are
received.

Reporting Current or Selected Values

Command: +A8E?

Response: +A8E:

,,[,][,][,]

Example:

+A8E: 1,1,00,1,0,0

For the defaults

Reporting Supported Range of Parameter Values

Command: +A8E=?

Response: +A8E: ( range),( range),(v8cf in octets),

( range),(),()

Example: +A8E:

(1,6),(1,5),(0,21,C1),(0,1),(0),(0)

+A8I: - CI Signal Indication

This indication is issued by an answering modem, if +A8E,

≠ 0, to indicate

detection of a V.8 CI signal, and report the recovered Call Function octet(s).

Indication Syntax

+A8I:

Defined Values

A hexadecimal code octet representation of those Call
Function octet(s). +A8I:0 indicates that the modem timed out
waiting for CI.

Example

+A8I:0

The modem timed out waiting for CI.

+A8I:X YYY