Change the default system password, Webmin, Point your browser at: https://dm-ats:10000 – Comtrol DM ATS-LNX User Manual
Page 10

Installation and Setup
10
Webmin
6.
Change the default system password.
dm-ats:~# passwd
Enter new UNIX password: [
enter new_password]
Retype new UNIX password: [
retype new_password]
passwd: password updated successfully
dm-ats:~#
7.
Run the ./newsshkeys.sh shell script in the user root home directory, which
automatically generates a new SSH key.
Note: All ATS-LNX units are shipped with the same default SSH key. If you
do not change the key, somebody else will be able to decrypt your SSH
traffic.
8.
Run the ./netconfig.sh shell script in the user root home directory to configure
the network settings on the ATS-LNX. The default network settings are:
•
eth0: 192.168.255.252 (Ethernet #2)
•
eth1: 192.168.250.251 (Ethernet #1)
Note: The ATS-LNX provides Ethernet ports that function as two independent
Ethernet network interface cards.
See
Network Card Installation and Configuration
PCMCIA network configuration
9.
Edit the /etc/resolv.conf file to modify the IP address.
10. Confirm that the /etc/nsswitch.conf file contains this line:
hosts: files dns
11. Connect Ethernet cables to the ports that you configured.
12. Ping the ATS-LNX to verify proper network configuration.
Webmin
The ATS-LNX is shipped with the Webmin remote administration package
leaving Webmin on the system, you should change the default root Webmin
password.
Use this procedure to change the root Webmin password from a remote PC.
1.
Point your browser at
where dm-ats is the IP address or host name of the ATS-LNX.
Depending on your browser, you may get a security alert and be advised that
the device does not have a security certificate.
2.
Log in as root; devicemaster is the default Webmin password and it is case-
sensitive.
PCMCIA knock-out removed,
SERIAL PORTS 1-8 connector and fanout
cable, if RocketPort PC104 option ordered.
if option ordered
eth1
eth0