beautypg.com

Lp gas model only, Connect regulator with hose to your lp gas tank, Check all connections for lp gas leaks – Kenmore 141.16315800 User Manual

Page 18

Attention! The text in this document has been recognized automatically. To view the original document, you can use the "Original mode".

background image

LP Gas Model only:

Connect Regulator with Hose to your LP Gas Tank

Turn all Burner Valves to the OFF position.

Inspeot the valve eonneetion port and regulator

assembly for damage or debris. Remove any
debris. Never use damaged or plugged equip­
ment.
Connect the regulator assembly to the tank valve
and HAND TIGHTEN nut clockwise to a full stop.
DO NOT use a wrench to tighten because it could
damage the Quick Coupling Nut and result in a
hazardous condition.

Open the tank valve 1/4 to 1/2 of a turn (coun­

terclockwise) and use a soapy water solution to
check all connections for leaks before attempting
to light your grill. See

"Checking for LP Gas

Leaks".

If a leak is found, turn the tank valve off

and do not use your grill until the leak is repaired.

Check all connections for LP Gas Leaks

Never

test for leaks with a flame. Prior to first use,

at the beginning of each season, or every time
your LP Gas tank is changed, you must check for
gas leaks. Follow these three steps:

□ Make a soap solution by mixing one part liquid

detergent and one part water.

□ Turn the grill Control Knobs to the full OFF

position, then turn the gas ON at source.

□ Apply the soap solution to all gas connections

indicated by the arrows. See diagram. If
bubbles appear in the soap solution the
connections are not properly sealed. Check
each fitting and tighten or repair as necessary.

CAUTION;

When the appliance is not in use the gas

must be turned off at the tank.

Place dust cap on cylinder valve outlet whenever the
cylinder is not in use. Only install the type of dust
cap on the cylinder valve outlet that is provided with
the cylinder valve. Other types of caps or plugs may

result in leakage of propane.

If you have a gas leak that cannot be repaired

by tightening, turn off the gas at the source,
disconnect fuel line from your grill and call

1-800-4-MY-HOIVIE® or your gas supplier for repair

assistance.

Disconnecting A Liquid Propane Gas (LPG)

Tank From Your Griii

□ Make sure the Burner Valves and LP Gas tank

valve are off. (Turn clockwise to close.)

□ Detach the hose and regulator assembly from

the LP Gas tank valve by turning the Quick
Coupling Nut counterclockwise.

18