NORMAL INSTALLATION STEPS

Step 1

Provide Adequate Gas Supply

The range is designed to operate at a pressure of 4
inches of water column on natural gas op if designed
for LP gas (propane or butane), 10 inches of water
column, M ake sure the range is supplied with the type
of gas for which it is designed If, at any time in the
future, the range is to be supplied with a different type
of gas, conversion adjustm ents must be made by a
qualified service technician before attem pting to oper­
ate the range on that gas

For proper operation, the pressure of natural gas sup­
plied to the regulator m ust be between 4 and 13 inch­

es of water column For LP gas, the pressure supplied
m ust be between 10 and 13 inches of water column

W hen checking for proper operation of the regulator,

the inlet pressure must be at least 1 inch greater than

the operating (manifold) pressure as given above. The

pressure regulator located at the inlet of the range
m anifold must rem ain in the supply line regardless of

whether natural or LP gas is being used. A flexible

m etal appliance connector used to connect the range

to the gas supply line should have an LD. of 1/2" and

be 5 feet in length (shorter and longer lengths are
acceptable) for ease of installation

Step

2

Connect the Range to Gas

Before disconnecting the old range, shut off the m ain
gas supply valve and leave it off until new hook-up
has been completed

Because hard piping restricts movement of the range,
the use of an A.G.A.-certified flexible metal appliance
connector is recom mended unless local codes require
a hard-piped connection Never use an old connector
when installing a new range

To prevent gas leaks, wrap pipe thread tape with

Teflon* around, or put pipe joint compound on, all
m ale (external) pipe threads

•Teflon: Registered trademark of DuPont

Gas Pipe and Electric Outlet Locations:

Flexible Connector Hookup Rigicf Pipe Hookup

Pressure fleguiator

J L

J L

Adapter

Nipple Adapter g0-

'

1

..'

^

Elbow

=3

Black iron Pipe

Manifold Pipe Fiex Connector

}TT|

Adapter

a

Adapter

Gas shut-off valve.

Nipple

'/2"

or%'

-Gas pipe

Instalier: inform the consumer
of the locailort of She gas

shut-off valve

1. Install a manual gas iine shut-off vaive in the gas
line in an easily accessed location outside of the
range

M ake

sure

everyone

operating

the

range

knows where and how to shut off the gas supply to the
range.

2. install male 1/2" flare union adapter to the 1/2" NPT
interna! thread at inlet of pressure regulator.

3. install male 1/2" or 3/4" flare union adapter to the
NPT internal thread of the manual shut-off valve, tak­
ing care to back up the shut-off valve to keep it from
turning

4. Connect flexible metal appliance connector to the
adapter on the range. Position range to permit con­
nection at the shut-off valve.

(continued next page)