beautypg.com

Warning, Troubleshooting – Kenmore ASPIRADORA 116.29914 User Manual

Page 24

Attention! The text in this document has been recognized automatically. To view the original document, you can use the "Original mode".

background image

TROUBLESHOOTING

Review this table to find do-it-yourself solutions for minor performance problems. Any other
service needed should be performed by a Sears or other qualified service agent

^WARNING

Always turn off and unplug vacuum cieaner before performing maintenance to the
vacuum cleaner. Failure to do so could result in electrical shock or personal
injury.

PROBLEM

Vacuum cleaner won't
start.

POSSIBLE CAUSE

1. Unplugged at wail outiel,

2. Tripped circuit breaker/btown

fuse at household service panel.

3. Loose hose electrical

oonnecilons

POSSIBLE SOLUTION

1. Plug in firmly, push ON/OFF switch

to on

2, Reset circuit breaker or replace fuse

3 . Reconnect hose ends..

Poor job of dirt

pick-up.

1, Full or clogged dust bag

2, Clogged airflow passages.
3, Dirty filters.

Wrong pile height setting.
Wrong power level selected.

Hole in hose.

Worn PowerMaSe agitator.
Worn or broken belt

Dirty agitator or end caps..
Canister hood open

11. Tripped overload protector in

PowerMate

1, Change bag

2, Clear airflow passages
3, Change fillera..
4, Adjust setting
5, Adjust control
6, Replace hose.
7, Change agitator,

8 & 9- See BELT CHANGING AND

AGITATOR CLEANING

10. Close and latch hood

11. Remove any items tha! may be

caught or jammed, then reset If

vacuum cleaner starts and stops
again, clean agitator and end caps,

then reset

Vacuum cleaner starts
but shuts off.

1 Hose or hood electrical

cormeciions.

2. Tripped overload protector in

PowerMate

3. Tripped thermal protector

in canister.

1. Check connections, reconnect hose

ends

2. Remove any items that may be

caught or jammed, then reset If

vacuum cleaner starts and stops
again, dean agitator and end caps,
then reset.

3. See PERFORMANCE FEATURES -

"Thermal Protector,"

PowerMate wiii not
run when attached.

1. PowerMate connections

unplugged,

2- Worn or broken beit.
3. Dirty agitator or end caps,
4, Tripped overtoad protector in

PowerMate

5,. Switch rrot it? CARPET position,

1. Plug in firmly

2 & 3. See BELT CHANGfNG AND

AGITATOR CLEANING

4. Remove any items that may be

caught or jammed, then reset If

vacuum deaner starts and slops

again, clean agitator and end caps,
then reset,

5. Move switch to CARPET position.

24

This manual is related to the following products: