background image

DAY/TIME

User Manual 28

Programmable Fan Mode

Programmable Fan Mode is selected by pressing

FAN until PROG appears in the display. It is only

available in programmable mode.
Programmable Fan Mode allows the user to run
the fan continuously during a selected program
event. To use this feature, select fan ON while
setting program events. (See “Setting Your

Program Schedule”, page 13).

Compressor Protection

Compressor protection is enabled/disabled

in the Installer Settings (See Installer Manual).

If enabled, this feature is automatically present in

cooling and/or heating modes.
This thermostat includes an automatic compressor protection delay to avoid potential damage to your system
from short cycling. This feature activates a short delay after turning off the system compressor.
Additionally, for multi-stage heat pump systems, this thermostat provides cold weather compressor protection by
locking out the compressor stage(s) of heating for a period of time after a power outage greater than 60 minutes.
This cold weather compressor protection can be manually overridden at any time by changing the system mode
to OFF momentarily, then back to HEAT.