Review Set Temperature
1. Press and hold button. The current set point temperature will be displayed in the
place of the current room temperature, and the indicator
SET will be displayed.
2. The display will return to normal operating mode when the button is released.
The
SET indicator will turn off indicating that the current temperature shown in the
display is the room temperature. Continuing to hold the button for 3 seconds or
longer will allow the user to change the current set point temperature.
NOTE:
The installer can reset the thermostat and bypass the compressor protection feature by pressing the RESET
button. This will erase all user program settings and should only be used during installation for testing purposes or to
reset a thermostat to regain normal operation. This will return all thermostat settings to their default values.
Changing Set Temperature
Compressor Protection Feature
1. Press and hold button at the same time for 3 seconds. The entire display
will flash once and the
SET indicator will be flashing. Release the button
and press the button again as desired to adjust the set temperature.
2. The display will return to normal operating mode after 5 seconds.
3. The SET indicator will turn off in the display indicating that the current temperature
shown in the display is the room temperature.
NOTE:
Once you have finished setting the temperature differential, you can wait 5 seconds and the thermostat will
automatically return to the normal operating mode.
NOTE:
To erase all user program settings, gently press RESET button using a paperclip or a small pencil tip.
This will return all thermostat settings to their default values.
cont.
This thermostat includes an automatic compressor protection feature to avoid potential damage to the cooling system from
short cycling. This thermostat automatically provides a 5-minute delay after turning off the cooling system output to protect
the compressor.
Programming User Settings
4
Temperature Adjustment
5
Additional Operation Features
6
5
Resetting Thermostat
Low Battery Detection and Replacement
Replacing the Batteries
1. Open the battery compartment door.
2. Gently remove the two "AA" alkaline batteries located in the battery compartment.
3. Install two new "AA" alkaline batteries into battery compartment. Make sure to match the positive (+) ends of the
batteries with the positive (+) terminals located in the battery compartment.
4. Close battery compartment and verify that the low battery indicator does not appear in the display.
The Reset feature allows the user to completely reset the thermostat to register new manual switch settings and return to
factory set software settings. To erase all entered settings, gently press
RESET button using a paper clip or a small pencil tip.
cont.
Thermostat does not
turn on system.
Check to see if
OFF is shown in display. This indicates that the
system is turned off at the thermostat. Move the system selector
switch to the
ON position.
Compressor protection features may be in effect due to
compressor short cycle conditions. See Compressor Protection
Feature, section 6 for a full explanation of this feature.
System may be malfunctioning. Call a professional service
technician immediately to verify system operation.
SYMPTOM
POTENTIAL SOLUTION
This thermostat requires two (2) properly installed "AA" alkaline batteries to provide power for the thermostat to properly
control the system operation.
This thermostat is equipped with a low battery detection feature that constantly monitors
the batteries during normal operating mode to determine whether they have sufficient
power to provide proper operation.
When this feature determines that the battery status is low, a low battery indicator will appear
in the display. It is recommended that the batteries be replaced immediately to maintain
system operation and program settings.
Additional Operation Features
6
Battery Replacement
7
COOL
Status Indicators
HEAT: The word “HEAT” will appear in the display when the
heating system is running.
COOL: The word “COOL” will appear in the display when the
cooling system is running.
Troubleshooting
8