5050_14_15.pdf, Troubleshooting, Wiring diagrams – Braeburn 5050 User Manual

Page 8: Symptom potential solution

background image

SYMPTOM

POTENTIAL SOLUTION

Thermostat will not
allow me to program
a setpoint
temperature higher
than 90˚ F (32˚ C).

This is above the normal thermostat temperature setting range

of 45˚ to 90˚ F (7˚ to 32˚ C).

Thermostat will not
allow me to program
a setpoint
temperature lower
than 45˚ F (7˚ C).

This is below the normal thermostat temperature setting range

of 45˚ to 90˚ F (7˚ to 32˚ C).

Thermostat will not
allow me to change
the setpoint.

The Keypad is locked. Press both the and key together at

the same time for one second to unlock (See section 5.5).

Fan Runs
intermittently or when
system is OFF.

Fan switch is in Recirculate (

®

) Mode.

Fan continues to run
all the time whether
the system is on
or off.

Check that the fan control switch is in the

AUTO position. This

will allow the fan to run only when the heating or cooling system

is turned on and running.
Check thermostat wiring to make sure that the fan control

wiring is connected to the correct terminals on the wiring

terminal block. See Installation and Wiring Diagrams sections

of this manual.

The room is too
warm or too cold.

The thermostat does
not allow me to
program each day
separately.

Change from Weekday-Weekend to 7 Day Mode

(see section 4.4).

Thermostat is in Adaptive Recovery Mode- (see section 5.6).

14

15

TROUBLESHOOTING

6

cont.

WIRING DIAGRAMS

7

Rc Rh

G

Factory Installed

Jumper

Typical 4-Wire Single Transformer Heating and Cooling System

W

Y

B

O

Heat

Control

Fan

Control

Cool

Control

24 Volt AC

Transformer

120

Volt AC

Hot Side

Transformer

Rc Rh

G

Remove

Factory Installed

Jumper

Typical 5-Wire Two Transformer Heating and Cooling System

W

Y

B

O

Heat

Control

Fan

Control

Cool

Control

Cool 24 VAC

Transformer

Heat 24 VAC

Transformer

120

Volt AC

120

Volt AC

Hot Side

Heat

Transformer

Hot Side

Cool

Transformer

System turns on
prior to the end of a
setback period.

See Review Set Temperature section of this manual to verify the

current setpoint and make any modifications that are necessary.

NOTES:

1. For Heating or Cooling Only System, ignore opposite connection.

2. For 2-Wire 24 Volt AC or 250mv - 750mv Millivolt Heating Systems,

ignore cooling connection and fan control.