cont.
PROGRAMMING
4
4.2
Setting Current Time of Day and Day of Week
NOTE:
It is important for you to set the current time of day (note AM/PM indicator in
display), and the current day of week correctly to avoid problems with program execution.
PROGRAMMING
4
4.1
Default Thermostat Settings
Function
Status After Reset
Operation Mode
Normal Operating Mode
Temperature Hold
Extended and Temporary Hold Cleared
Clock
12:00 pm, Monday
Room Temperature
70˚ F (21.0˚ C), to be renewed within
5 seconds
Setpoint Temperature
According to system switch:
62˚ F (17.0˚ C) for Heat or Off
83˚ F (28.0˚ C) for Cool
Temperature Scale
˚F or ˚C dependent on switch setting
Operating Program
DAY program, Monday
Low Battery Warning
Off, to be renewed within 5 seconds
Temperature Differential
0.5˚ F (0.25˚ C)
Residual Cooling Fan Delay
60 seconds
Short Cycle Protection Timer Reset
Output Relays
Off
Extended Hold
Indefinite
Keypad Lock
Unlocked
Adaptive Recovery Mode
Reset
Filter Check Monitor
0 Days OFF
Recirculating Fan Timer
Reset with 120 minute off cycle
NOTE:
The thermostat will return to normal operating mode automatically after 15
seconds if no key is pressed. It will also return to normal operating mode immediately if
the RETURN button is pressed.
1. When in normal operating mode, press the DAY/TIME
keypad button. The LCD display will be cleared
except for the time, am/pm indicator and the day of
the week. The hour portion of the time will flash.
2. Press the or button to set the current hour.
3. Press DAY/TIME button again, the minute portion of
the time will flash.
4. Press the or button to set the current minute.
5. Press DAY/TIME button again, the day of the week indicator will flash.
6. Press the or button to set the current day of the week.
7. Press DAY/TIME button again and the thermostat will return to normal operating mode.
4.3
Setting Thermostat User Options
The default setting is 0.5˚ F (0.25˚ C). The room temperature must change 0.5˚ F (0.25˚ C) from
the setpoint temperature before the thermostat will initiate the system in heating or cooling.
NOTE:
Once you have finished setting the temperature differential you can wait 15
seconds and the thermostat will automatically return to the normal operation mode.
Otherwise, you can press RETURN button again to set the Residual Cooling Fan Delay.
Setting the Temperature Differential
Setting Residual Cooling Fan Delay
The default setting is 60 seconds. During the
COOL mode of operation, the fan will stay on for
60 seconds after the setpoint has been satisfied, and the compressor has turned off.
3. After pressing the RETURN button again, the display
will show "
FAN XX," where "XX" is the fan delay
time in seconds.
Setting the Extended Hold Time (see also section 5.3)
The default setting is Long (indefinite) Hold. If the HOLD feature is activated, the current setpoint
will be held until HOLD is released.
6. After pressing the RETURN button again, the display
will show "
HOLD LG", where LG is indefinite hold.
HOLD
Setting the Filter Check Monitor (see also section 5.4)
10. Press the or button to change the Filter Monitor
interval to the desired value of 0 (disabled), 30, 60,
90, 120, or 180 days.
11. Press the RETURN button again to set the Recirculating Fan cycle, or wait 15 seconds for
the thermostat to return to the normal mode.
FILT
The default user options are compatible with most systems and applications. They are
normally set at the time of installation and usually do not require any modification under
normal operating conditions. If you wish to change these settings, simply follow the
instructions below.
NOTE:
The temperature differential settings are the same for both the heating and
cooling systems.
1. In normal operating mode, press and hold the
RETURN button for 4 seconds. The LCD display
will show "
d1 X", where "X" equals the ˚F / ˚C
differential setting. This is the current temperature
differential setting.
2. Press the or button to set the temperature
differential to your desired setting of 0.5˚, 1˚, or 2˚ F
(0.25˚, 0.5˚, or 1˚ C).
4. Press the or button to change the Residual
Cooling Fan Delay to the desired setting of 0 (disabled),
30, 60, or 90 seconds.
5. Press the RETURN button again to set the Extended
Hold Time or wait 15 seconds to return to the normal mode.
7. Press the or button to change the Extended
Hold time from indefinite (
LG) to 24 hours (SH).
8. Press the RETURN button again to set the Filter Check
Monitor or wait 15 seconds for the
thermostat to
return to the normal mode.
The default setting is 0 days (Filter Monitor disabled).
9. After pressing the RETURN button again, the display
will show "
FILT XXX SET", where XXX is the Filter
Monitor interval (number of days since last warning).