Programming user settings – Braeburn 2200 User Manual

Page 3

background image

4

Default Thermostat Settings

Setting Thermostat User Options

Setting Current Time of Day and Day of Week

5

cont.

Programming User Settings

4

NOTE: It is important for you to set the current time of day (note AM/PM indicator

in display), and the current day of week correctly to avoid problems with

program execution.

1. When in normal operating mode, press the

DAY/TIME keypad button. The LCD display

will be cleared except for the time, am/pm
indicator and the day of the week. The
hour portion of the time will flash. Press
the or button to set the current hour.
2. Press the DAY/TIME button again. The minute portion of the time will flash.
Press the or button to set the current minute.
3. Press the DAY/TIME button again. The day of the week indicator will flash.
Press the or button to set the current day of the week.
4. Press the DAY/TIME button again and the thermostat will return to normal

operating mode.

Programming User Settings

NOTE: The thermostat will return to normal operating mode automatically after

30 seconds if no key is pressed. It will also return to normal operating mode

immediately if the RETURN button is pressed.

The default user options are compatible with most systems and applications.
They are normally set at the time of installation and usually do not require
modification under normal operating conditions. If you wish to change these
settings, simply follow the instructions below.

Setting First Stage Differential

NOTE: The temperature differential settings are the same for both the heating

and cooling systems.

The default setting is 0.5˚ F (0.25˚ C).
The room temperature must change .5˚ F
(0.25˚ C) from the set point temperature
before the thermostat will initiate the
system in heating or cooling.

1. In normal operating mode, press and hold the RETURN button for 4 seconds.
The LCD display will show "

SET D1 x˚", where "x" equals the ˚F / ˚C

differential setting. This is the current first stage differential setting.
2. Press the or buttons to set the first stage differential to your desired

setting of .5˚, 1˚, or 2˚ F (.2˚, .5˚ or 1˚ C).

NOTE – MODEL 2000, 2000NC: Once you have finished setting the first stage

differential, you can wait 15 seconds and the thermostat will return to the

normal operating mode. Or you can press the RETURN button to return to normal

operating mode.

NOTE – MODEL 2200, 2200NC: If you do not wish to change the second stage

differential, wait 30 seconds and the thermostat will automatically return to the

normal operating mode.

Setting Second Stage Differential (Model 2200, 2200NC)
The default setting is 2˚ F (1.0˚ C). The room
temperature must change 2˚ F (1.0˚ C) in
addition to the first stage differential setting
before the thermostat will initiate the
second stage of the system in heating.

1. Press and hold the RETURN button again and the LCD display will show “SET
D2 x˚
”, where “x” equals the ˚F / ˚C differential setting. This is the current

second stage differential setting.
2. Press the or buttons to set the second stage differential to your desired
setting of 2˚, 3˚, 4˚, 5˚ or 6˚ F (1˚, 1.5˚, 2˚, 2.5˚ or 3˚ C).

NOTE – MODEL 2200, 2200NC: Once you have finished setting the second

stage differential, wait 30 seconds and the thermostat will return to the normal

operating mode.
NOTE:
To erase all user program settings, gently press RESET button using a

paper clip or a small pencil tip. This will return all thermostat settings to their

default values, erasing all program settings entered by the user.

4

Function

Status After Reset

Operation Mode

Normal Operating Mode

Temperature Hold

Permanent and Temporary Hold Cleared

Clock

12:00 p.m., Monday

Room Temperature

70˚ F (21.0˚ C), to be renewed within

5 seconds

Set Point Temperature

According to System Switch

62˚ F (17.0˚ C) for Heat and Off

83˚ F (28.0˚ C) for Cool

Temperature Scale

˚F or ˚C dependent on switch setting

Operating Program

DAY program, Monday

Low Battery Warning

Off, to be renewed within 5 seconds

1st Stage Differential

0.5˚ F (0.25˚ C)

2nd Stage Differential

2˚ F (1.0˚ C)

Short Cycle Protection Timer Reset
Output Relays

Off

Filter Check Monitor

0 days-off

Extended Hold

Indefinite

Adaptive Recovery Mode

Off