Programming user settings – Braeburn 2200 User Manual
Page 3
![background image](/manuals/661686/3/background.png)
4
Default Thermostat Settings
Setting Thermostat User Options
Setting Current Time of Day and Day of Week
5
cont.
Programming User Settings
4
NOTE: It is important for you to set the current time of day (note AM/PM indicator
in display), and the current day of week correctly to avoid problems with
program execution.
1. When in normal operating mode, press the
DAY/TIME keypad button. The LCD display
will be cleared except for the time, am/pm
indicator and the day of the week. The
hour portion of the time will flash. Press
the or button to set the current hour.
2. Press the DAY/TIME button again. The minute portion of the time will flash.
Press the or button to set the current minute.
3. Press the DAY/TIME button again. The day of the week indicator will flash.
Press the or button to set the current day of the week.
4. Press the DAY/TIME button again and the thermostat will return to normal
operating mode.
Programming User Settings
NOTE: The thermostat will return to normal operating mode automatically after
30 seconds if no key is pressed. It will also return to normal operating mode
immediately if the RETURN button is pressed.
The default user options are compatible with most systems and applications.
They are normally set at the time of installation and usually do not require
modification under normal operating conditions. If you wish to change these
settings, simply follow the instructions below.
Setting First Stage Differential
NOTE: The temperature differential settings are the same for both the heating
and cooling systems.
The default setting is 0.5˚ F (0.25˚ C).
The room temperature must change .5˚ F
(0.25˚ C) from the set point temperature
before the thermostat will initiate the
system in heating or cooling.
1. In normal operating mode, press and hold the RETURN button for 4 seconds.
The LCD display will show "
SET D1 x˚", where "x" equals the ˚F / ˚C
differential setting. This is the current first stage differential setting.
2. Press the or buttons to set the first stage differential to your desired
setting of .5˚, 1˚, or 2˚ F (.2˚, .5˚ or 1˚ C).
NOTE – MODEL 2000, 2000NC: Once you have finished setting the first stage
differential, you can wait 15 seconds and the thermostat will return to the
normal operating mode. Or you can press the RETURN button to return to normal
operating mode.
NOTE – MODEL 2200, 2200NC: If you do not wish to change the second stage
differential, wait 30 seconds and the thermostat will automatically return to the
normal operating mode.
Setting Second Stage Differential (Model 2200, 2200NC)
The default setting is 2˚ F (1.0˚ C). The room
temperature must change 2˚ F (1.0˚ C) in
addition to the first stage differential setting
before the thermostat will initiate the
second stage of the system in heating.
1. Press and hold the RETURN button again and the LCD display will show “SET
D2 x˚”, where “x” equals the ˚F / ˚C differential setting. This is the current
second stage differential setting.
2. Press the or buttons to set the second stage differential to your desired
setting of 2˚, 3˚, 4˚, 5˚ or 6˚ F (1˚, 1.5˚, 2˚, 2.5˚ or 3˚ C).
NOTE – MODEL 2200, 2200NC: Once you have finished setting the second
stage differential, wait 30 seconds and the thermostat will return to the normal
operating mode.
NOTE: To erase all user program settings, gently press RESET button using a
paper clip or a small pencil tip. This will return all thermostat settings to their
default values, erasing all program settings entered by the user.
4
Function
Status After Reset
Operation Mode
Normal Operating Mode
Temperature Hold
Permanent and Temporary Hold Cleared
Clock
12:00 p.m., Monday
Room Temperature
70˚ F (21.0˚ C), to be renewed within
5 seconds
Set Point Temperature
According to System Switch
62˚ F (17.0˚ C) for Heat and Off
83˚ F (28.0˚ C) for Cool
Temperature Scale
˚F or ˚C dependent on switch setting
Operating Program
DAY program, Monday
Low Battery Warning
Off, to be renewed within 5 seconds
1st Stage Differential
0.5˚ F (0.25˚ C)
2nd Stage Differential
2˚ F (1.0˚ C)
Short Cycle Protection Timer Reset
Output Relays
Off
Filter Check Monitor
0 days-off
Extended Hold
Indefinite
Adaptive Recovery Mode
Off