beautypg.com

5 additional operation features – Braeburn 7320 User Manual User Manual

Page 29

background image

5 Additional Operation Features

Auto Changeover Mode

Auto Changeover mode is a feature enabled/disabled in the

Installer Settings (see Installer Guide). If enabled, it is selected

by touching the SYSTEM TouchPad

until AUTO HEAT or AUTO

COOL appears below the TouchPad.
When Auto Changeover mode is enabled and selected, the system
automatically switches between heating and cooling when the
room temperature meets the programmed heating or cooling set
points. To operate properly, the thermostat requires a “dead band”
setting to eliminate program conflicts. The dead band is set in the
Installer Settings (See Installer Guide). The default setting is 3° F.

Therefore, you will not be able to set your heat or cool temperature
within 3° F of each other. If a setting is made in either heating or cooling which violates the dead band, the
opposite mode will adjust up or down automatically to maintain the programmed dead band spacing.

HUMID

29 User Manual