beautypg.com

Ac programming specifications, Ac i2c specifications – Cypress enCoRe CY7C64215 User Manual

Page 25

background image

CY7C64215

Document 38-08036 Rev. *C

Page 25 of 30

AC Programming Specifications

The following table lists guaranteed maximum and minimum specifications for the voltage and temperature ranges: 4.75V to 5.25V
and 0°C < T

A

< 70°C, or 3.0V to 3.6V and 0°C < T

A

< 70°C, respectively. Typical parameters apply to 5V and 3.3V at 25°C and are

for design guidance only.

AC I

2

C Specifications

The following table lists guaranteed maximum and minimum specifications for the voltage and temperature ranges: 4.75V to 5.25V
and 0°C < T

A

< 70°C, or 3.0V to 3.6V and 0°C < T

A

< 70°C, respectively. Typical parameters apply to 5V and 3.3V at 25°C and are

for design guidance only.

Table 25. AC Programming Specifications

Parameter

Description

Min

Typ

Max

Unit

Notes

T

RSCLK

Rise Time of SCLK

1

20

ns

T

FSCLK

Fall Time of SCLK

1

20

ns

T

SSCLK

Data Set up Time to Falling Edge of SCLK

40

ns

T

HSCLK

Data Hold Time from Falling Edge of SCLK

40

ns

F

SCLK

Frequency of SCLK

0

8

MHz

T

ERASEB

Flash Erase Time (Block)

10

ms

T

WRITE

Flash Block Write Time

30

ms

T

DSCLK

Data Out Delay from Falling Edge of SCLK

45

ns

Vdd

> 3.6

T

DSCLK3

Data Out Delay from Falling Edge of SCLK

50

ns

3.0 < Vdd < 3.6

Table 26. AC Characteristics of the I

2

C SDA and SCL Pins for Vdd

Parameter

Description

Standard Mode

Fast Mode

Unit

Notes

Min

Max

Min

Max

F

SCLI2C

SCL Clock Frequency

0

100

0

400

kHz

T

HDSTAI2C

Hold Time (repeated) START Condition. After
this period, the first clock pulse is generated.

4.0

0.6

μs

T

LOWI2C

LOW Period of the SCL Clock

4.7

1.3

μs

T

HIGHI2C

HIGH Period of the SCL Clock

4.0

0.6

μs

T

SUSTAI2C

Setup Time for a Repeated START Condition

4.7

0.6

μs

T

HDDATI2C

Data Hold Time

0

0

μs

T

SUDATI2C

Data Setup Time

250

100

[12]

ns

T

SUSTOI2C

Setup Time for STOP Condition

4.0

0.6

μs

T

BUFI2C

Bus Free Time Between a STOP and START
Condition

4.7

1.3

μs

T

SPI2C

Pulse Width of spikes are suppressed by the
input filter.

0

50

ns

Note

12. A Fast-Mode I2C-bus device can be used in a Standard-Mode I2C-bus system, but the requirement tSU;DAT Š 250 ns must then be met. This automatically

be the case if the device does not stretch the LOW period of the SCL signal. If such device does stretch the LOW period of the SCL signal, it must output the
next data bit to the SDA line trmax + tSU;DAT = 1000 + 250 = 1250 ns (according to the Standard-Mode I2C-bus specification) before the SCL line is released.