Connecting to the controller, Panel lock, Installation procedure – KEYENCE CA-MP120 User Manual
Page 2: Connecting the 24 vdc power source, Adjustment procedure, Specifications, Dimensions, Panel lock installation procedure
2
1. The PANEL LOCK will activate when the automatic adjustment indicator lights up.
2. The PANEL LOCK will be deactivated when the PANEL LOCK button is pressed.
1. Insert the CA-MP120 into the panel.
2. Using the 6 installation hooks on the top and bottom of the CA-MP120, tighten the screws
of the mounting bracket using a Phyllis-head screwdriver.
The CA-MP120 can not only be installed to the panel bracket, it can be installed to the
monitor stand for CA Series LCD monitor use (optional). For details inquire to your nearest
KEYENCE office.
If your monitor needs adjustment due to ambient light, the installation angle, or the
characteristics of the connected device, follow the procedure below.
1. Press the
button on the rear of the monitor. The setting menu is displayed.
2. Press the
button to move the cursor onto the item to change the setting.
3. Press the
button to change the setting of the item.
4. Press the
button to change the value/setting.
5. Press the
button to return to the status of step 1.
6. When you complete the adjustment, press the
button to exit the setting menu.
LCD monitor CA-MP120
Panel mounting diagram
Panel cut measurement
Connecting to the controller
Image signal
input
Connect by using an RGB monitor cable OP-66842 (3 m), an OP-87055
(10 m), or a commercially available analog RGB cable.
PANEL LOCK
Installation Procedure
• Tightening the mounting bracket with excessive force may deform
the casing. The proper tightening torque for achieving the drip-proof
feature is 0.3 Nm. However, note that a drip-proof effect may not be
obtained depending on the strength or shape of the panel.
• When installing the CA-MP120, make sure to leave a minimum
clearance of 20 mm around the product.
Connecting the 24 VDC Power Source
• Use electrical wiring AWG14 to AWG22.
• Make sure to connect the frame ground terminal for the 24 VDC
power source to a type D ground.
• The sizes of solderless connectors are shown below. Use connectors
that fit M3 screws.
• Tighten the screws with a torque of 0.5 to 0.75 Nm.
Adjustment Procedure
When no video signal is input, a blue screen (with message "NO SYNC
SIGNAL" for the first five minutes) is displayed instead of the setting menu.
Auto-escape function
If no button is pressed for about 10 seconds, the setting menu display is
turned off. When this occurs, the change(s) made so far will be saved.
Panel (Panel thickness): 1.0 to 4.0 mm
2
1
Mounting hook
Screw
Mounting bracket
Mounting bracket
Phillips screwdriver
NOTICE
NOTICE
5.8 mm or
smaller
Circular connector
5.8 mm or smaller
Y connector
Reference
MENU
MENU
MENU
EXIT
Reference
Item
Setting
BRIGHTNESS
Adjusts the brightness of the backlight of the LCD panel.
CONTRAST
Adjusts the contrast of the image.
COLOR MODE
Adjusts the color tone of RGB individually.
BLACK LEVEL
Adjusts the black level.
CLOCK
Adjusts the horizontal size of the screen by adjusting the
clock.
FOCUS
Reduces blurred characters and images by adjusting the
focus.
POSITION
Adjusts the horizontal/vertical position of the screen.
*1
AUTO
ADJUSTMENT
The input image signal is adjusted automatically to the most
appropriate setting.
Adjustment object: POSITION/CLOCK/FOCUS
POWER
SAVING
The screen is set when the screen automatically lights up or
when the PANEL LOCK is set. The PANEL LOCK is
deactivated by the
button.
BUTTON LOCK
All button operations are deactivated.
Also the
button operation is deactivated.
The lock is released when the
button is pressed for 3
seconds or more.
INFORMATION
Displays the device setting information, etc.
RECALL
Resets the settings to the factory default (initial) settings.
Specifications
Product name
LCD Monitor
Model
CA-MP120
Display element
a-Si, TFT active matrix method
Display color
16,777,216
No. of dots
1024 (W) x 768 (H) dots or 800 (W) x 600 (H) dots
Active display area
245 (W) x 184 (H) mm
Backlight
Approx. 100,000 hours (average)
(When installed in an upright position under 25°C (77°F))
Input signal
Analog RGB signal (0.7 Vp-p, 75
Ω), Horizontal/vertical
synchronization signal
Input signal mode
1024 (W) x 768 (H), Vertical frequency: 60 Hz or
800 (W) x 600 (H), Vertical frequency: 60 Hz
Input connector
High-density D-sub 15-pin female (3-way, inch screw)
Power-supply voltage
24 VDC ±10%
Current consumption
1.5 A max.
Ambient temperature
0 to +40°C (32 to 104°F)
Relative humidity
35 to 85%
Construction
Panel-mount type
Only the front face is dust-proof and splashproof equivalent to IP65
Weight
Approx. 2.3 kg
The TFT LCD panels may have bright dots that always illuminate and dark
dots that never illuminate. This is inevitable due to the manufacturing
process and is not a product failure.
Dimensions
PANEL LOCK
PANEL LOCK
MENU
Reference
(49.5)
6
186
(Active display area)
247.4
(Active display area)
360
15
6.5
255
55.5
28
342
240
35
75
75
4-M4
Depth: 10
(Unit: mm)
Mounting screw
Mounting bracket
157.5
242+1
0
344 +1
0
Panel thickness 1.6 to 4.0 mm
263
(Mounting bracket
external dimensions)
156.5
(Unit: mm)