beautypg.com

Terminal block interface, Specifications, Dimensions – KEYENCE CA-DC30E User Manual

Page 2: Warranties and disclaimers, Buyer's transfer obligations

background image

Copyright (c) 2014 KEYENCE CORPORATION. All rights reserved.

13068E 1074-1 96M13068 Printed in Japan

When using the CA-DC30E and the CC-Link expansion unit at the same time

Connect the CC-Link expansion unit CA-NCL10E directly to the controller, and then

connect the CA-DC30E to the left side of the CC-Link expansion unit.

[For the XG-8000 Series]

Terminal block interface

*1 The environmental resistance for the LED illumination unit is surrounding air

temperature: 0 to 40

o

C, and surrounding air humidity: 35 to 65% RH (No

condensation).

*2 The temperature range depends on the surrounding temperature of the connected

controller.

CA-DC30E (with the attachment installed)

(1) KEYENCE warrants the Products to be free of defects in materials and

workmanship for a period of one (1) year from the date of shipment. If any
models or samples were shown to Buyer, such models or samples were used
merely to illustrate the general type and quality of the Products and not to
represent that the Products would necessarily conform to said models or
samples. Any Products found to be defective must be shipped to KEYENCE
with all shipping costs paid by Buyer or offered to KEYENCE for inspection and
examination. Upon examination by KEYENCE, KEYENCE, at its sole option, will
refund the purchase price of, or repair or replace at no charge any Products
found to be defective. This warranty does not apply to any defects resulting
from any action of Buyer, including but not limited to improper installation,
improper interfacing, improper repair, unauthorized modification,
misapplication and mishandling, such as exposure to excessive current, heat,
coldness, moisture, vibration or outdoors air. Components which wear are not
warranted.

(2) KEYENCE is pleased to offer suggestions on the use of its various Products.

They are only suggestions, and it is Buyer's responsibility to ascertain the
fitness of the Products for Buyer’s intended use. KEYENCE will not be
responsible for any damages that may result from the use of the Products.

(3) The Products and any samples ("Products/Samples") supplied to Buyer are not

to be used internally in humans, for human transportation, as safety devices or
fail-safe systems, unless their written specifications state otherwise. Should any
Products/Samples be used in such a manner or misused in any way, KEYENCE
assumes no responsibility, and additionally Buyer will indemnify KEYENCE and
hold KEYENCE harmless from any liability or damage whatsoever arising out of
any misuse of the Products/Samples.

(4) OTHER THAN AS STATED HEREIN, THE PRODUCTS/SAMPLES ARE

PROVIDED WITH NO OTHER WARRANTIES WHATSOEVER. ALL
EXPRESS, IMPLIED, AND STATUTORY WARRANTIES, INCLUDING,
WITHOUT LIMITATION, THE WARRANTIES OF MERCHANTABILITY,
FITNESS FOR A PARTICULAR PURPOSE, AND NON-INFRINGEMENT OF
PROPRIETARY RIGHTS, ARE EXPRESSLY DISCLAIMED.
IN NO EVENT SHALL KEYENCE AND ITS AFFILIATED ENTITIES BE
LIABLE TO ANY PERSON OR ENTITY FOR ANY DIRECT, INDIRECT,
INCIDENTAL, PUNITIVE, SPECIAL OR CONSEQUENTIAL DAMAGES
(INCLUDING, WITHOUT LIMITATION, ANY DAMAGES RESULTING FROM
LOSS OF USE, BUSINESS INTERRUPTION, LOSS OF INFORMATION, LOSS
OR INACCURACY OF DATA, LOSS OF PROFITS, LOSS OF SAVINGS, THE
COST OF PROCUREMENT OF SUBSTITUTED GOODS, SERVICES OR
TECHNOLOGIES, OR FOR ANY MATTER ARISING OUT OF OR IN
CONNECTION WITH THE USE OR INABILITY TO USE THE PRODUCTS,
EVEN IF KEYENCE OR ONE OF ITS AFFILIATED ENTITIES WAS ADVISED
OF A POSSIBLE THIRD PARTY’S CLAIM FOR DAMAGES OR ANY OTHER
CLAIM AGAINST BUYER.
In some jurisdictions, some of the foregoing
warranty disclaimers or damage limitations may not apply.

BUYER'S TRANSFER OBLIGATIONS:

If the Products/Samples purchased by Buyer are to be resold or delivered to a third
party, Buyer must provide such third party with a copy of this document, all
specifications, manuals, catalogs, leaflets and written information provided to Buyer
pertaining to the Products/Samples.

E 1101-3

The illumination expansion unit CA-DC30E can be connected together with

the CA-DC21E. The maximum number of units that can be connected in this

situation is four (eight individual lighting units), but, among these units, the

maximum number of CA-DC30E units that can be connected is two (four

individual lighting units).

The CC-Link expansion unit cannot be connected to the left side of

the CA-DC30E. Incorrect connections may damage the controller and

peripheral equipment.

Specifications

Output

Light adjustment

system

Constant current control

Tone

Digital 255 levels

[Selectable with controller]

No. of

connections

2 ch. (Six-pole circular connector for RayTrax LED illuminations)

Synchronism

Synchronized with trigger applied to camera and with shutter speed

Light adjustment

responsiveness Within 1 ms

Display

LED display

When illumination is recognized:

Green

When a disconnection error occurs: Red

Rating

Power voltage

Power

consumption

24 VDC ±10%

5.0 A

Value at maximum load including the inrush current at startup

Environmental

resistance *

1

Surrounding air

temperature

Surrounding air

humidity

0 to 50

o

C *

2

35 to 85% RH (No condensation)

Weight

Approx. 430 g

Dimensions

Reference

Attachment
(supplied with the
illumination expansion unit)

Illuminationexpansion unit
CA-DC30E

CC-Link unit
CA-NCL10E

NOTICE

(1) 24VDC + power supply (24 VDC) input

(2) 0V

- power supply (0 V) input

(3) FG

Connect the ground wire

Applicable wire: AWG14 to 22

Terminal block screw torque: 0.25 Nm or less

Power connector

(1)

(3)

6

150.5

22.95

90

117.5

38

7

65.3

35.9

83.3

122.3

25.2

16.5

74

2-M4
Depth: 6

[Front]

[Side]

[Bottom]

Warranties and Disclaimers