Main specifications – KEYENCE CV-X200 Series User Manual
Page 7
7
*1 The letter at the end of the model number means the difference of the installed software function. For details, see the
"
CV-X Series User's Manual
"
.
*2 The PNP open collector is used for model types with P at the end.
*3 Models that have an Ethernet port installed on the CPU unit support Ethernet port direct connections.
*4 The CA-DC21E supports switching between PWM and DC methods. The CA-DC30E is Constant current control method and the CA-DC10E is fixed to the PWM method.
Main Specifications
Model name
*1*2
CV-X270
CV-X250
CV-X200
Number of pixels
With CA-HX500C/HX500M connected
• 5,000,000-pixel mode:
2432 (H) x 2040 (V), approx. 4,960,000 pixels
• 2,000,000-pixel mode:
1600 (H) x 1200 (V), approx. 1,920,000 pixels
With CA-HX200C/HX200M connected
• 2,000,000-pixel mode:
1600 (H) x 1200 (V), approx. 1,920,000 pixels
With CA-HX048C/HX048M connected
• 470,000-pixel mode:
784 (H) x 596 (V), approx. 470,000 pixels
• 310,000-pixel mode:
640 (H) x 480 (V), approx. 310,000 pixels
• 240,000-pixel mode:
512 (H) x 480 (V), approx. 240,000 pixels
With CV-H500C/H500M connected
• 5,000,000-pixel mode:
2432 (H) x 2050 (V), approx. 4,990,000 pixels
With CV-200C/S200C/H200C/200M/S200M/
H200M connected
• 2,000,000-pixel mode:
1600 (H) x 1200 (V), 1,920,000 pixels
• 1,000,000-pixel mode:
1024 (H) x 960 (V), approx. 980,000 pixels
With CV-H100C/H100M connected
• 1,000,000-pixel mode:
1000 (H) x 1000 (V), approx. 1,000,000 pixels
With CV-035C/S035C/035M/S035M/H035C/
H035M connected
• 310,000-pixel mode:
640 (H) x 480 (V),
approx. 310,000 pixels
• 240,000-pixel mode:
512 (H) x 480 (V),
approx. 240,000 pixels
With CA-HX200C/HX200M connected
• 2,000,000-pixel mode:
1600 (H) x 1200 (V), approx. 1,920,000 pixels
With CA-HX048C/HX048M connected
• 470,000-pixel mode:
784 (H) x 596 (V), approx. 470,000 pixels
• 310,000-pixel mode:
640 (H) x 480 (V), approx. 310,000 pixels
• 240,000-pixel mode:
512 (H) x 480 (V), approx. 240,000 pixels
With CV-200C/S200C/H200C/200M/S200M/
H200M connected
• 2,000,000-pixel mode:
1600 (H) x 1200 (V), 1,920,000 pixels
• 1,000,000-pixel mode:
1024 (H) x 960 (V), approx. 980,000 pixels
With CV-H100C/H100M connected
• 1,000,000-pixel mode:
1000 (H) x 1000 (V), 1,000,000 pixels
With CV-035C/S035C/035M/S035M/H035C/
H035M connected
• 310,000-pixel mode:
640 (H) x 480 (V),
approx. 310,000 pixels
• 240,000-pixel mode:
512 (H) x 480 (V),
approx. 240,000 pixels
With CA-HX048C/HX048M connected
• 470,000-pixel mode:
784 (H) x 596 (V), approx. 470,000 pixels
• 310,000-pixel mode:
640 (H) x 480 (V), approx. 310,000 pixels
• 240,000-pixel mode:
512 (H) x 480 (V), approx. 240,000 pixels
With CV-035C/S035C/035M/S035M/H035C/
H035M connected
• 310,000-pixel mode:
640 (H) x 480 (V),
approx. 310,000 pixels
• 240,000-pixel mode:
512 (H) x 480 (V),
approx. 240,000 pixels
Camera input
2 Colour/monochrome cameras, four cameras
with the expansion unit CA-E800
(Supports CA-HX500C/HX500M/HX200C/
HX200M/HX048C/HX048M and CV-H500C/
200C/S200C/H200C/H100C/035C/S035C/
H035C/H500M/200M/S200M/H200M/H100M/
035M/S035M/H035M, mixed connection possible)
2 Colour/monochrome cameras, four cameras
with the expansion unit CA-E800
(Supports CA-HX200C/HX200M/HX048C/
HX048M and CV-200C/S200C/H200C/H100C/
035C/S035C/H035C/200M/S200M/H200M/
H100M/035M/S035M/H035M, mixed connection
possible)
2 Colour/monochrome cameras
(Supports CA-HX048C/HX048M and CV-035C/
S035C/H035C/035M/S035M/H035M, mixed
connection possible)
Main processor for image processing
Multi-core DSP (High-Speed)
Multi-core DSP (Medium)
Multi-core DSP (Standard)
Number of setting registrations
Up to 1000 settings (depending on SD card capacity and setting contents) for SD card 1 and SD card 2 individually and external switching is possible
Number of reference images
Each setting supports 900 images per camera (depending on SD card capacity), compress and save functions and image registration of position
adjusted images.
Memory card
• SD card slot x2 (SDHC compatible)
• Supports OP-87133 (512 MB: standard equipment on the SD1 slot for the CV-X250/X200), CA-SD1G (1 GB: standard equipment on the SD1 slot for
the CV-X270), CA-SD4G (4 GB)
Interface
Control input
External trigger
input
4 points (2 of which support special function assignment)
Input rating: 26.4 V max., 3 mA min, simultaneous/individual capture with up to 4 cameras (two camera with the CV-X200) is possible
Can set individual trigger delays (0 to 999 ms) for each trigger input
Control input
16 points (4 of which support special function assignment) Input rating: 26.4 V max., 2 mA min.
Control output
Common output
27 points (11 of which support special function assignment, includes 4 high speed outputs), NPN open collector, 50 mA max. (30 V max.)
Total status output
1 point, NPN open collector, 50 mA max. (30 V max.) Supports total status hold control, one-shot output (1 to 9999 ms)
Monitor output
Analogue RGB output
XGA 1024 x 768 (24 bit colour, 60Hz)
Operation indicator
Power supply, operation, ERROR LED display
RS-232C
Can perform numerical value output, control input/output, and switching the functions of CA series touch panel interface, supports a max. baud rate of
up to 230400 bps (Cannot be used with PLC-Links using the RS-232C port)
PLC-Link
• Can output numerical values and perform control input/output using the Ethernet or RS-232C port
(Cannot be used in conjunction with EtherNet/IP and PROFINET. When using the RS-232C port, nonprocedural RS-232C communication cannot be
used in conjunction.)
• The following PLCs are supported via link unit:
*3
KEYENCE: KV-700 Series, KV-1000 Series, KV-3000 Series, KV-5000 Series, KV-5500 Series, KV Nano Series
Mitsubishi Electric: MELSEC A Series (RS-232C only), Q Series, L Series, FX Series (RS-232C only)
OMRON: SYSMAC C Series (RS-232C only), CJ/CS1/CP1 Series
YASKAWA Electric Corporation: MP900 Series (RS-232C only)/MP2000 Series
Ethernet
• Can output numerical values and perform control input/output
• Can output measured value and image data via the included PC programme, upload and download settings
• Supports FTP client and FTP server function
• VNC server (for non-PC clients, only displaying the monitor screen is supported)
• Supports BOOTP function
• 1000BASE-T/100BASE-TX/10BASE-T
USB
• Can output measured value and image data via the included PC programme, upload and download settings
• USB 2.0 only.
EtherNet/IP
• Numerical value and control input/output using the Ethernet port enabled (Cannot be used in conjunction with PLC-link / PROFINET).
• Cyclic (implicit) communication (max. 1436 bytes) possible. Message communication possible.
• Maximum connections: 32.
• In conformity with conformance test Version.CT10.
PROFINET
• Numerical value and control input/output using the Ethernet port enabled (Cannot be used in conjunction with PLC-link / EtherNet/IP).
• Cyclic communication (max. 1408 bytes) possible. Record data communication possible.
• In conformity with Conformance Class A
Mouse
Possible to control various menus via an optional dedicated mouse (OP-87506: included with the controller)
Touch panel
Possible to operate settings via CA series touch panel using TOUCH PANEL port or RS-232C port
(When RS-232C is used, the nonprocedural communication and PLC-Links that use the RS-232C port cannot be used.)
Illumination control
By connecting the optional Illumination Expansion Unit CA-DC30E/DC21E/DC10E, lighting and intensity control for the LED illumination is possible.
*4
CA-DC30E: 2ch/unit, up to 2 units can be connected, only supports dedicated illumination unit.
CA-DC21E: 2ch/unit, up to 4 units can be connected, Output voltage 12V/24V.
CA-DC10E: 2ch/unit, up to 1 unit can be connected, Output voltage 12V only, mixed connection with CA-DC30E/DC21E is not possible.
Language
Switched among English, Japanese, Simplified Chinese, Traditional Chinese, Korean, Thai, German, French, Italian, Mexican Spanish, Indonesian,
Vietnamese, and Portuguese (Brazilian)
Rating
Power supply voltage
24 V DC ± 10%
Current consumption
3.6A (2 cameras connected)/4.6A (4 cameras connected)
Figures indicate maximum load including rush current at start-up.
3.4A (When 2 cameras are connected)
Figures indicate maximum load including rush
current at start-up.
Environmental
resistance
Ambient temperature
0 to +45°C
Relative humidity
35 to 85% RH (no condensation)
Weight
Approx. 1600g