Linear potentiometers with resistance values 4k7 ... 100k can be used. We recommend 10k
(linear).

Momentary or toggle switches can be used in two different ways:

state of rest

aktive state

Midi data

voltage

Midi data

voltage

version 1

0

0V

127

+5V

version 2

127

+5V

0

0V

Simple momentary switches (1 contact, open at rest) or simple toggle switches (1 contact on/off)
are required. According to the desired behaviour (version 1 or 2 in the above table) the switch
has to be wired correspondingly:

In both cases an additional 10k resistor is required (possible range 4k7 to 100k) to pull the
analog input to a defined state during the switch is open.

• Version 1: The resistor is soldered between GND and the control voltage input 1...16. This

way the input is pulled to GND ( =0V corresponding to Midi data 0) as long as the switch is
left open. When the switch is closed the voltage jumps to +5V corresponding to Midi data
127.

• Version 2: The resistor is soldered between +5V and the control voltage input 1...16. This

way the input is pulled to +5V (corresponding to Midi data 127) as long as the switch is left
open. When the switch is closed the voltage jumps to 0V corresponding to Midi data 0.

Sixteen 10k-resistors (range 4k7 ... 100k) are enclosed witch each PE delivery. Suitable
resistors are available in each electronic shop too (value: 10k, power: ¼ W, tolerance: 5%,
material: carbon).

Unused inputs have to be connected to GND. Avoid open inputs ! An open input will cause the
transmission of random Midi data causing undesirable side effects at the Midi receiver (e.g. Midi
overflow or random parameter fluctuations).