Install zp logger software – Checkline ZP User Manual

Page 4

background image

page 17

page 4

Installing Microsoft .NET Framework

Microsoft .NET Framework 1.1 or later must be installed prior to
running ZP Logger software. If Microsoft.NET Framework 1.0 has
been previously installed it must be removed.

1. Check to see if you already have the .NET Framework installed

by clicking Start on your Windows desktop, selecting Control
Panel, and then double-clicking the Add or Remove Programs
icon. When that window appears, scroll through the list of appli-
cations. Highlight and remove all .NET applications earlier than
version 1.1. If you see Microsoft .NET Framework 1.1 listed, you
do not need to install it again. Proceed to install ZP Logger.

2. Once you have removed ver-

sions earlier than 1.1 or if
no Framework is installed,
insert Driver CD-ROM
included with your Imada
force gauge. Double click
the DOTNET folder and
install the dotnetfx package by double-clicking the icon.

3. Eject Driver CD-ROM and restart the computer.

Install ZP Logger software

1. Insert the Driver CD-ROM and open the

ZPR folder. Double click the ZP Logger
icon.

2. Follow the on screen instructions:
3. Choose “close” when installation is

complete.

4. Eject the Driver CD-ROM.

PREPARATION

To connect the remote sensor to the ZPS display unit, rotate the
round connector to find the matching groove, then push it in
until positive connection is made. To disconnect, first slide the
ribbed cover of the connector back, then pull out the connector
(DO NOT ROTATE THE CONNECTOR WHEN PULLING OUT).

OPERATION

Selecting Units

Press

to turn on the gauge. The LCD display briefly shows the

capacity of the gauge and then zero with a measuring unit (facto-

ry setup is lbf). If you want to change to other units:

1. Turn off the gauge.

2. Press

again while holding

to enter Power-Off program-

ming mode (CF9 flashes with solid nn0).

3. Press

to display U-03 with a unit, then press

or

to

cycle desired units (ozf or lbf, gf or kgf, and N), and press

to select (CF9 flashes with solid End).

4. Press

to exit 1st. programming mode.

Once units are selected, the gauge retains them as a default.

ROTATE CONNECTOR TO FIND THE
GROOVE

LM

'S' TYPE

BOX TYPE

PUSH IN UNTIL IT MAKES A
POSITIVE CONNECTION

SLIDE BACK RIBBED COVER,
THEN PULL OUT CONNECTOR

RIBBED COVER

REMOTE SENSORS

DPU both tension and compression
Low capacity: Box Type (±0.2% F.S.; ±1 LSD)
High capacity: S Type (±0.2% F.S.; ±1 LSD)

LM compression only (±0.5% F.S.; ±1 LSD)
IMPORTANT: Load applying surface must be flat