3. External Switch Display Freeze

By connecting #10 and #12 of the
communications port, the gauge
instantaneously captures the criti-
cal reading and holds the display
from remote locations.

4. External Switch Display Clear

By connecting #8 and #12 of the communications port, dis-
play can be cleared from remote locations.

(1) Pay extra attention to avoid overload as display

value will not change during display hold.

(2) Use contact closure only and DO NOT apply

voltage across #10 and #12 port pins.

Use contact closure only and DO NOT apply voltage
across #8 and #12 port pins.

2. ±2 VDC Analog Signal

Connect the CB-104 analog cable to the communications port
and the device receiving the data.

RECHARGING Ni-MH BATTERY

1. To maximize battery life, power automatically shuts off after

10 minutes of non-use or user-defined interval. Auto shut off
is bypassed during USB output or when using the AC
adapter/charger.

2. The battery icon flashes when the gauge needs

to be recharged. It takes 10 hours to charge fully.

3. Push

to turn off power. Only use the IMADA

AC adapter/ charger provided, AD120 for
115VAC, AD230 for 230VAC. Plug into the correct AC output.

4. When the gauge is turned off, make sure the AC adapter/charger

is disconnected to avoid overcharging.

Optional Cables

CB-104 10' Analog cable

CB-204 10' RS-232C cable, 9 pin female

Optional Handle

The OH-1 fits ZP gauges. Constructed of high qual-
ity steel for rugged use, the handle facilitates
measurement of heavy loads. Complete with
mounting screws.

NG

00.0

peak

N

OK

+NG

OV

ER

LO

AD

ZER

O

SEND

PEAK

ON
OFF

Optional Adapter Plate

AP-001 Adapter Plate mounts IMADA
low capacity gauges to most other
brands of test stands.
Use the 4 screws (supplied) to mount
the IMADA gauge to the AP-001
adapter plate. Then use the 2 PEM
nuts on the AP-001 adapter plate to
mount to other brands of test stand.

OTHER BRAND TEST STAND
2 MOUNTING PLATE BOLTS

GAUGE MOUNTING
SCREWS (4)

PEM NUTS

IMADA GAUGE

AP-001

FORCE CONTROL

Connect the Imada Z Series force gauges to an MX-
Series test stand and enable force controlled testing.
Force control can automatically stop testing when
the force value reaches the high setpoint programmed
on the Z Series force gauge, or maintain the force
between the High and Low setpoints. Force control
is ideal for fatigue or non-destructive testing.

MX-SERIES

TEST STAND

WITH ZP GAUGE

Optional Data Acquisition Software

ZP Recorder captures and processes 1,000 data/second using a USB
port.A graph of the data and statistics are displayed.Analyze all or part
of the data. Compare multiple graphs.
SW-1 software captures and analyzes force data using an RS-232 port.
A running log of data, graph and statistics are displayed.