8.1 Setting the Memory Mode

1. Turn the POWER off.

2. Press PEAK and hold, then press and release POWER.

The display will show the HI Comparator limit

3. Press PEAK twice to display the current memory mode.

4. Press UNIT to cycle the Memory mode

5. Press MEM to save and exit.

The following items are found in the Comparator/Memory mode settings.

Setting

Display

Content

Default Factory Setting

Comparator HI limit

HI

Current HI limit

0

Comparator LO limit

LO

Current LO limit

0

Memory Mode

MEM

Current Memory Mode

Std

– 19 –

PEAK

PEAK

PEAK

MEM

UNIT

UNIT

UNIT

PEAKPEAK

PEAKPEAK

PEAKPEAK

MEMORY

MEMORY

UNITUNIT

UNITUNIT

UNITUNIT

Setting the Memory Mode

8.2 Recording Memory Data

The following procedures explain how to activate memory recording for
each memory mode

Continuous Mode:

1. In the Continuous Measurement Mode, Press MEM to start recording.

The letter M will appear and start blinking. Press M to stop recording.

2. If 1000 points of data are recorded, the display will show FULL and

return to standard measurement mode.