Maintenance, Fault diagnostics – 360 Systems MAXX-2400SD User Manual
Page 92
____________________________________________________________________________________
Page 92
MAXX 2400 Owners Manual
MAINTENANCE
FAULT DIAGNOSTICS
Front Panel Indicators
The five LED indicators on the front panel are used to diagnose server fault conditions. The
meaning of each indicator is noted in the following table. During normal operation, all indicators
will be on, with the possible exception of Genlock (if Internal Sync is selected).
Repairs should be performed only by qualified electronics technicians.
GENLOCK
OFF indicates that the Genlock
setting in the System menu is
“Internal”
FLASHING indicates that Genlock is
selected in the System menu, but
there is no signal, or an invalid
signal, at the GENLOCK connector.
Check the Genlock setting in the On-
Screen System menu.
Check the Genlock cable connections
or signal.
POWER
FLASHING indicates that there is a
fault in the system power supply.
Shut down the Image Server and
contact 360 Systems Customer Support
for further hardware diagnosis.
FANS
FLASHING indicates that there is a
fault of the internal chassis fan.
Check the chassis and CPU fan
operation. Replace if necessary. Do
not run the Image Server without a
working fan.
DRIVES
FLASHING indicates that there is a
fault in the system RAID array.
Check the RAID array status using
the utility under
START > System > RAID STATUS.
SYSTEM
FLASHING indicates that the CPU
fan is running slow, or stopped; or
that the CPU temperature or voltage
is not within specification.
Shut down the Image Server and
contact 360 Systems Customer Support
for further hardware diagnosis.
ALL LED’s
FLASHING
Application Halt, Operating System
Halt, or Major System Fault
Attempt to perform a system shutdown
via GUI or momentary press of front
panel Power button.
Otherwise, hold the power button
down until the system powers off.
If flashing continues after restart
contact 360 Systems Tech Support.
Note: All LED’s flashing during system
startup is normal.