Panasonic WV-CP214 User Manual
Page 7
Attention! The text in this document has been recognized automatically. To view the original document, you can use the "Original mode".
(1) Auto Iris Lens Connector
This 4-pin connector supplies the power and DC
control signal to the auto iris lens.
(2) Flage-back Adjusting Ring
This ring is used to adjust the back focal length or
picture focus by rotating this ring.
(3) Lens (Option)
See page 10, 11, 12, 13 and 14 for details on lens
selection. Standard C-mount lens can be used
with the camera by use of optional lens mount
converter (C-mount adaptor) WV-AD20.
(4) Camera Mounting Screw Hole
This threaded hole (1/4* - 20) is used to mount the
camera onto a mounting bracket or tripod.
(5) Video Output Connector (VIDEO OUT)
A 1.0 Vp-p / 75 ohms composite video signal is
provided at this connector.
Whenever the multiplexed vertical drive (VD2) sig
nal is supplied to this connector, the camera syn
chronization mode is automatically set to Vertical
Drive Lock.
(6) AC Power Cord
(7) Power Indicator (POWER)
(8) Sync Selection Switch (LL/INT) (WV-CP210/
WV-CP214)
This switch is used to select the camera synchro
nization mode.
INT:
The camera synchronization mode is set to
internal 2 ; 1 interlace.
LL:
The camera synchronization mode is set to
Line-lock.
(9) AGC ON/OFF Switch (AGC, ON/OFF)
This switche is used to select the gain of the video
amplifier as follows.
ON:
When the lens iris is fully opened under a low
light condition, a clear picture is obtained by
automatic increase of the gain.
OFF:
A natural and low-noise picture is obtained
under a low light condition.
- 5 -