FOCUS OR FLANGE-BACK
ADJUSTMENT
The following adjustment should be made by qualified
service personnel or system installers.
1. Loosen screws on the flange-back adjusting ring.
PREVENTION OF BLOOMING AND
SMEAR
When the camera is faced toward spot light or other
bright lights and light reflecting objects, smear or
blooming may appear. Therefore, the camera should
be operated carefully in the vicinity of extremely bright
objects to avoid smear or blooming.
2. Turn the flange-back adjusting ring to the desired
position.
Caution;
Do not turn this ring too much to counterclockwise
as this could damage the inner glass and CCD
image sensor.
3. Tighten the screws on the flange-back adjusting
ring.
LENS MAINTENANCE AND
CLEANING
1. Remove the lens connector.
2. Remove the lens, and inspect the camera CCD
faceplate through the lens mount opening to
assure that the faceplate is free of smudges or
particles of dirt.
3. Clean the CCD faceplate, if necessary, using lens
tissue or a cotton tipped applicator and ethanol.
4. Install the new lens.
- 1 7 -