11 specifications, 1 dynamometer specifications, Chapter 11 specifications – Dillon EDXtreme (Red) User Manual

Page 63: Dynamometer specifications

background image

62

EDXtreme User Instructions

11 Specifications

11.1 Dynamometer Specifications

Enclosure:

Designed to NEMA4X/IP55. Suitable for continuous outdoor use.

Accuracy:

0.1% of capacity up to EDX-50T.*
0.3% of capacity for EDX-75T and above.*

Repeatability:

0.1% of capacity up to EDX-50T.*
0.3% of capacity for EDX-75T and above.*
* Normal resolution mode with Dillon provided shackles.

Proof Load:

150% of capacity up to EDX-75T.
110% of capcity EDX-100T and above.

Ultimate Overload:

See table on

page 64

.

Safe Overload:

200% of capacity

Body Protection:

Aluminum and alloy steel capacities are powder coated.

Bearings:

Unmatched repeatability attained by needle bearings in shackle pin holes up to EDX-5T.
Shackle pin acts as inner race.

Shackles:

Forged industry standard anchor shackles. Models up to EDX-5T use precision machined
shackle pin. Higher capacities use bar stock pin.

Display:

128 x 64 dot-graphic LCD display shows up to 6 digits 1.0” (26 mm) high plus annunciators and
softkeys. Digits are .11 inches (3 mm) thick for unmatched readability.

Display Update Rate:

2 times per second.

Peak Capture Rate:

10/100/1,000 Hz

Connector:

Recessed sealed connector may be used for serial communications or connection to a
Communicator II remote.

RS-232
Communication:

Print or extract data easily. Continuous output can drive a scoreboard. Configurable poll
character.

Calibration:

Traceable to the National Institute of Standards and Technology. Certificate included with curve
of readings. Passes only with three consecutive confirming runs, with all points in specification.

Battery Life:

Stand alone EDXtreme with no radio and no backlight lasts up to 400+ hours. 40 hours
continuous with Radio Link System. Use with two C-Cell alkaline batteries. (When using
backlight, battery life will be reduced, depending on intensity.)

Operating
Temperature:

-4° F to 158° F (-20° to 70° C)

Included with
Instrument:

All include certificate of calibration, manual and batteries. Plastic carry case included for EDX-
1T to EDX-50T. Higher capacities include rugged plywood storage crate. Instruments with
shackles include centering spacers (EDX-20T & up) and shackle storage crate (EDX-20T to
EDX-75T). Display backlight.

Options:

Shackles. Radio communications.

Approval:

CE