EDXtreme User Instructions
Holdoff Seconds:
Once the unit has recorded this overload, how
much time will pass before this unit will re-arm
and allow to record the overload again.
Comm Port:
This allows you to choose where to export the
"ON PRINT" logged data.
a. EDX = Cell
b. COMM = Com1
c. RADIO = Future development
d. Disabled = to turn off
ID
An operater can key in either a User ID number or a Lift ID assigned to a
particular product. This is a numeric number only and can be any number
from 1 to 65,000. (if you want to turn the ID off, key in 0).
Send
This will export/send the Log information out the configured port.
Clear
This will clear any data in the Log mode. Clearing "On Lift", "Timed" and
"Overload" stored data.
Note: All Log Modes will record Date and Time along with it's force and peak reading.