Service OAM
9145EMP NID Software User’s Manual
Maintenance Entity Groups
147
•
To remove a peer MEP, type 2 and press Enter. You are prompted for the MEP ID
number. Type the number and press Enter.
•
When all the peer MEPs have been configured, type A to accept and press Enter.
•
Press Esc to return to the Maintenance Entity Group Attributes screen
8. You can change the Permissions (Sender ID). Type 5 and press Enter. Select None,
Chassis, Manage, ChassisManage, or Defer, and press Enter.
9. When you are finished, type A to accept and press Enter.
10. Press Esc to return to the Maintenance Entity Group List screen.
Figure 11-16 Maintenance Entity Group Attributes screen
Canoga Perkins Corp. Ethernet Network Interface Device 21-MAR-2010
Model 9145EMP-761-0-0 V11.02 F11 00:11:01
---------------------MAINTENANCE ENTITY GROUP ATTRIBUTES------------------------
MEG ID:100 Name: test-meg
Name Format: ICC-based Format
Level: 2
1) CCM Interval: 1 sec
VLAN Tag Type: C-Tag
VLAN Multiplexing record. 100
VLAN List: N/A
2) Add VLAN to VLAN List.
3) Remove VLAN from VLAN List.
4) View/Modify Peer MEPs list.
5) Permissions (Sender ID): None
Select [1-6] for attributes:
------------------------------------Messages-----------------------------------