6diagnostics menu, 1loopback setup, Diagnostics menu -17 – CANOGA PERKINS L351 10/100BASE Media Converter User Manual
Page 36: Loopback setup -17, 6 diagnostics menu, 1 loopback setup

EdgeAccess Universal Chassis System
L351 10/100BASE Media Converter
4-17
4.6
Diagnostics Menu
Use the Diagnostics menu for troubleshooting the L351; you can view current loopback conditions
and set up loopback. See Figure 29. For details about using loopback, see Chapter 3. To use the
Diagnostics, follow these steps:
1. From the Main Menu, type
2
, "Diagnostics," and press
2. Type the number for the test option you want, and press
3. When you finish running diagnostic tests, press
DIAGNOSTICS
1) Loopback Setup
2) Remote Latency/Jitter Test
Figure 29. Diagnostics Menu
4.6.1 Loopback Setup
Use the Loopback Setup report and menu to view current loopback conditions and set up loopback for
troubleshooting the L351. See Figure 30 and Table 8. For details about using loopback, see
Chapter 3. To run a loopback test, follow these steps:
1. From the Diagnostics menu, type
1
, "Loopback Setup," and press
screen appears.
2. Type the number for the loopback option you want to set, press
column if needed, press
3. When you finish running Loopback, press
LOOPBACK SETUP
Local
Remote
Chassis/Slot
4/3B
2/5
Loopback Switch Setting:
N/A
N/A
Loop Test MAC Address:
00 40 2A 80 58 32
00 40 2A 80 58 33
1) Loopback Option Control
Software
Software
2) Loopback State
Disabled
Disabled
3) Swap MAC Address
at Loopback Point?
Yes
Yes
4) Recalculate CRC
at Loopback Point?
Yes
Yes
Figure 30. Loopback Setup Screen