3trap configuration, Trap configuration -9, 3 trap configuration – CANOGA PERKINS L351 10/100BASE Media Converter User Manual
Page 28

EdgeAccess Universal Chassis System
L351 10/100BASE Media Converter
4-9
REMOTE VLAN TAG TRANSLATION TABLE
User Port
Ext Port
In VLAN
Out VLAN
Out VLAN
In VLAN
-------
--------
--------
-------
1)
1
3
54
2
2)
2
2
3
2
3)
0
0
0
0
4)
0
0
0
0
5)
0
0
0
0
6)
0
0
0
0
7)
0
0
0
0
8)
0
0
0
0
9) Enable VLAN
Translation? No
No
Figure 19. Remote VLAN Tag Translation Table Screen
REMOTE P-BIT TRANSLATION TABLE
User Port
Ext Port
1) Incoming P-Bit 0 translated to
0
0
2) Incoming P-Bit 1 translated to
1
1
3) Incoming P-Bit 2 translated to
2
2
4) Incoming P-Bit 3 translated to
3
3
5) Incoming P-Bit 4 translated to
4
4
6) Incoming P-Bit 5 translated to
5
5
7) Incoming P-Bit 6 translated to
6
6
8) Incoming P-Bit 7 translated to
7
7
9) P=Bit Translation Enabled?
No
No
Figure 20. Remote P-Bit Translation Table Screen
4.5.3 Trap Configuration
Traps are messages to alert network management about conditions. The DMM logs the traps and the
DMM or Model 1020 transmits them by SNMP to the network manager. At the Trap Configuration
screen, enable or disable traps individually or use the "Master Trap Control" to enable or disable all
traps. See Figure 21. To configure traps, follow these steps:
1. From the Main Menu, type
1
, "System Configuration," and press
Configuration menu appears.
2. From the System Configuration menu type 3, "Trap Configuration," and press
3. At the Trap Configuration menu, type the number for a trap and press
Note: "Master Trap Control" enables or disables all traps. The factory default is Disabled.
4. Press
5. To return to the System Configuration menu, press