7. Handling and storage

Store in accordance with local regulations. Store in a segregated and approved area.
Store in original container protected from direct sunlight in a dry, cool and well-ventilated
area, away from incompatible materials (see Section 10) and food and drink. Eliminate
all ignition sources. Separate from oxidizing materials. Keep container tightly closed
and sealed until ready for use. Containers that have been opened must be carefully
resealed and kept upright to prevent leakage. Do not store in unlabeled containers.
Use appropriate containment to avoid environmental contamination.

dissipate static electricity during transfer by grounding and bonding containers and
equipment before transferring material. Empty containers retain product residue and
can be hazardous. Do not reuse container.

Storage

:

heptane

ACGIH TLV (United States, 3/2012).
TWA: 400 ppm 8 hours.
TWA: 1640 mg/m³ 8 hours.
STEL: 500 ppm 15 minutes.
STEL: 2050 mg/m³ 15 minutes.
OSHA PEL 1989 (United States, 3/1989).
TWA: 400 ppm 8 hours.
TWA: 1600 mg/m³ 8 hours.
STEL: 500 ppm 15 minutes.
STEL: 2000 mg/m³ 15 minutes.
NIOSH REL (United States, 1/2013).
TWA: 85 ppm 10 hours.
TWA: 350 mg/m³ 10 hours.
CEIL: 440 ppm 15 minutes.
CEIL: 1800 mg/m³ 15 minutes.
OSHA PEL (United States, 6/2010).
TWA: 500 ppm 8 hours.
TWA: 2000 mg/m³ 8 hours.

methylcyclohexane

ACGIH TLV (United States, 3/2012).
TWA: 1610 mg/m³ 8 hours.
TWA: 400 ppm 8 hours.
NIOSH REL (United States, 1/2013).
TWA: 1600 mg/m³ 10 hours.
TWA: 400 ppm 10 hours.
OSHA PEL (United States, 6/2010).
TWA: 2000 mg/m³ 8 hours.
TWA: 500 ppm 8 hours.
OSHA PEL 1989 (United States, 3/1989).
TWA: 1600 mg/m³ 8 hours.
TWA: 400 ppm 8 hours.

8. Exposure controls/personal protection

Engineering measures

:

Use only with adequate ventilation. Use process enclosures, local exhaust ventilation or
other engineering controls to keep worker exposure to airborne contaminants below any
recommended or statutory limits. The engineering controls also need to keep gas,
vapor or dust concentrations below any lower explosive limits. Use explosion-proof
ventilation equipment.

Recommended monitoring
procedures

:

If this product contains ingredients with exposure limits, personal, workplace
atmosphere or biological monitoring may be required to determine the effectiveness of
the ventilation or other control measures and/or the necessity to use respiratory
protective equipment. Reference should be made to appropriate monitoring standards.
Reference to national guidance documents for methods for the determination of
hazardous substances will also be required.