Toxicological information, Ecological information, Disposal considerations – Chemtronics Konform SR CTSR-12 User Manual
Page 9

Konform® SR - CTSR-12
11. Toxicological information
Conclusion/Summary
:
Not available.
Teratogenicity
Conclusion/Summary
:
Not available.
Reproductive toxicity
Conclusion/Summary
:
Not available.
12. Ecological information
Ecotoxicity
:
No known significant effects or critical hazards.
Aquatic ecotoxicity
acetone
Acute EC50 20.565 mg/l Marine water
Algae - Ulva pertusa
96 hours
Acute LC50 6000000 µg/l Fresh water
Crustaceans - Gammarus pulex
48 hours
Acute LC50 10000 µg/l Fresh water
Daphnia - Daphnia magna
48 hours
Acute LC50 100 mg/l Fresh water
Fish - Pimephales promelas -
Juvenile (Fledgling, Hatchling,
Weanling)
96 hours
Chronic NOEC 4.95 mg/l Marine water
Algae - Ulva pertusa
96 hours
Chronic NOEC 0.1 ml/L Fresh water
Daphnia - Daphnia magna -
Neonate
21 days
toluene
Acute EC50 433 ppm Marine water
Algae - Skeletonema costatum
96 hours
Acute EC50 12500 µg/l Fresh water
Algae - Pseudokirchneriella
subcapitata
72 hours
Acute EC50 11600 µg/l Fresh water
Crustaceans - Gammarus
pseudolimnaeus - Adult
48 hours
Acute EC50 6000 µg/l Fresh water
Daphnia - Daphnia magna -
Juvenile (Fledgling, Hatchling,
Weanling)
48 hours
Acute LC50 5500 µg/l Fresh water
Fish - Oncorhynchus kisutch - Fry 96 hours
Chronic NOEC 500000 µg/l Fresh water Algae - Pseudokirchneriella
subcapitata
96 hours
Chronic NOEC 1000 µg/l Fresh water
Daphnia - Daphnia magna
21 days
Product/ingredient name
Species
Result
Exposure
Conclusion/Summary
:
Not available.
Persistence/degradability
Conclusion/Summary
:
Not available.
Other adverse effects
:
No known significant effects or critical hazards.
The generation of waste should be avoided or minimized wherever possible. Disposal
of this product, solutions and any by-products should at all times comply with the
requirements of environmental protection and waste disposal legislation and any
regional local authority requirements. Dispose of surplus and non-recyclable products
via a licensed waste disposal contractor. Waste should not be disposed of untreated to
the sewer unless fully compliant with the requirements of all authorities with jurisdiction.
Waste packaging should be recycled. Incineration or landfill should only be considered
when recycling is not feasible. This material and its container must be disposed of in a
safe way. Empty containers or liners may retain some product residues. Do not
puncture or incinerate container.
Waste disposal
13. Disposal considerations
:
United States - RCRA Toxic hazardous waste "U" List
Acetone (I); 2-Propanone (I)
67-64-1
Listed
U002
Toluene; Benzene, methyl-
108-88-3
Listed
U220
Ingredient
CAS #
Status
Reference
number
9/13
0710
6/13/2013.