6. Accidental release measures
Stop leak if without risk. Move containers from spill area. Use spark-proof tools and
explosion-proof equipment. Approach release from upwind. Prevent entry into sewers,
water courses, basements or confined areas. Wash spillages into an effluent treatment
plant or proceed as follows. Contain and collect spillage with non-combustible,
absorbent material e.g. sand, earth, vermiculite or diatomaceous earth and place in
container for disposal according to local regulations (see Section 13). Dispose of via a
licensed waste disposal contractor. Contaminated absorbent material may pose the
same hazard as the spilled product. Note: see Section 1 for emergency contact
information and Section 13 for waste disposal.
Large spill
:
Store in accordance with local regulations. Store in a segregated and approved area.
Store away from direct sunlight in a dry, cool and well-ventilated area, away from
incompatible materials (see Section 10) and food and drink. Eliminate all ignition
sources. Use appropriate containment to avoid environmental contamination.
Put on appropriate personal protective equipment (see Section 8). Eating, drinking and
smoking should be prohibited in areas where this material is handled, stored and
processed. Workers should wash hands and face before eating, drinking and smoking.
Remove contaminated clothing and protective equipment before entering eating areas.
Pressurized container: protect from sunlight and do not expose to temperatures
exceeding 50°C. Do not pierce or burn, even after use. Do not ingest. Avoid contact
with eyes, skin and clothing. Avoid breathing gas. Avoid breathing vapor or mist. Use
only with adequate ventilation. Wear appropriate respirator when ventilation is
inadequate. Store and use away from heat, sparks, open flame or any other ignition
source. Use explosion-proof electrical (ventilating, lighting and material handling)
equipment. Use non-sparking tools. Empty containers retain product residue and can
be hazardous.
7. Handling and storage
Handling
Storage
:
:
hexane
ACGIH TLV (United States, 3/2012).
TWA: 500 ppm 8 hours.
TWA: 1760 mg/m³ 8 hours.
STEL: 1000 ppm 15 minutes.
STEL: 3500 mg/m³ 15 minutes.
OSHA PEL 1989 (United States, 3/1989).
TWA: 500 ppm 8 hours.
TWA: 1800 mg/m³ 8 hours.
STEL: 1000 ppm 15 minutes.
STEL: 3600 mg/m³ 15 minutes.
NIOSH REL (United States, 1/2013).
TWA: 100 ppm 10 hours.
TWA: 350 mg/m³ 10 hours.
CEIL: 510 ppm 15 minutes.
CEIL: 1800 mg/m³ 15 minutes.
propane
ACGIH TLV (United States, 3/2012).
TWA: 1000 ppm 8 hours.
NIOSH REL (United States, 1/2013).
TWA: 1800 mg/m³ 10 hours.
TWA: 1000 ppm 10 hours.
OSHA PEL (United States, 6/2010).
TWA: 1800 mg/m³ 8 hours.
TWA: 1000 ppm 8 hours.
OSHA PEL 1989 (United States, 3/1989).
TWA: 1800 mg/m³ 8 hours.
TWA: 1000 ppm 8 hours.
8. Exposure controls/personal protection