Chemtronics Flux-Off Rosin ES5535 User Manual

Page 2

background image

Material

Compatibility

ABS

Good

Buna-N

Good

EPDM

Poor

Graphite

Excellent

HDPE

Excellent

Kynar

Fair

LDPE

Fair

Lexan

Fair

Neoprene

Non-Compatible

Noryl

Good

Nylon

 66

Excellent

Cross-Linked PE

Excellent

Polypropylene

Good

Polystyrene

Not recommended

PVC

Good

Silicone Rubber

Not recommended

Teflon

Excellent

Viton

Excellent

Performance

Product Required for Rosin Removal

(mg solvent used to remove 1 mg rosin flux)

Flux-Off Rosin

101

Conventional Flux Remover

3673

Rosin Removal Rate (mg / in

2

sec.)

Flux-Off Rosin

4.0

Conventional Flux Remover

0.3


USAGE INSTRUCTIONS
For industrial use only.
Read MSDS carefully prior to use.
Spray 4-6” from surface to clean. Wash parts from
top to bottom, allowing the liquid to flush away dirt
and dissolved grease. For precise application use
attached extension tube. Product is Flammable - Do
not use near sources of ignition and energized
equipment.

TECHNICAL & APPLICATION
ASSISTANCE

Chemtronics provides a technical hotline to answer
your technical and application related questions. The
toll free number is: 1-800-TECH-401.


AVAILABILITY
ES1035

10 oz. Aerosol

ES1035

10 oz. BrushClean Aerosol

ES835B

5 oz. BrushClean Aerosol

ES135

1 gallon Liquid

ES535

5 gallon Liquid

ES5535

53 gallon Liquid

ENVIRONMENTAL IMPACT DATA

HCFC-141b
HCFC-225

None
None

HFC
nPB

Aerosol -Yes
None


Hydrochlorofluorocarbons (HCFCs) are regulated under the Montreal Protocol
as Class II ozone depleting substances. HCFC-141b is no longer produced in the
US under this legislation. HCFC-225 is planned for production phase-out in
2015. Hydrofluorocarbons (HFCs) are not currently regulated.
EPA has listed n-propyl bromide (nPB) as an acceptable alternative to ozone
depleting substances in metal, precision, and electronics cleaning under Section
612 of the Clean Air Act.


NOTE: This information is believed to be accurate.
It is intended for professional end users having the
skills to evaluate and use the data properly.

CHEMTRONICS does not guarantee the accuracy of
the data and assumes no liability in connection with
damages incurred while using it.


Chemtronics

 and Flux-Off are registered trademarks of

Chemtronics. All rights reserved.
All other trademarks herein are trademarks or registered
trademarks of their respective owners.


CHEMTRONICS
8125 COBB CENTER DRIVE
KENNESAW, GA 30152
1-770-424-4888

REV. C (08/13)


DISTRIBUTED BY: