beautypg.com

Handling and storage, Exposure controls/personal protection – Chemtronics CircuitWorks® Flex Conductive Pen CW2900 User Manual

Page 4

background image

CircuitWorks® Flex Conductive Pen

Store in accordance with local regulations. Store in a segregated and approved area.
Store in original container protected from direct sunlight in a dry, cool and well-ventilated
area, away from incompatible materials (see Section 10) and food and drink. Eliminate
all ignition sources. Separate from oxidizing materials. Keep container tightly closed
and sealed until ready for use. Containers that have been opened must be carefully
resealed and kept upright to prevent leakage. Do not store in unlabeled containers.
Use appropriate containment to avoid environmental contamination.

Put on appropriate personal protective equipment (see Section 8). Eating, drinking and
smoking should be prohibited in areas where this material is handled, stored and
processed. Workers should wash hands and face before eating, drinking and smoking.
Remove contaminated clothing and protective equipment before entering eating areas.
Do not get in eyes or on skin or clothing. Do not breathe vapor or mist. Do not ingest.
Use only with adequate ventilation. Wear appropriate respirator when ventilation is
inadequate. Do not enter storage areas and confined spaces unless adequately
ventilated. Keep in the original container or an approved alternative made from a
compatible material, kept tightly closed when not in use. Store and use away from heat,
sparks, open flame or any other ignition source. Use explosion-proof electrical
(ventilating, lighting and material handling) equipment. Use non-sparking tools. Take
precautionary measures against electrostatic discharges. To avoid fire or explosion,
dissipate static electricity during transfer by grounding and bonding containers and
equipment before transferring material. Empty containers retain product residue and
can be hazardous. Do not reuse container.

7. Handling and storage

Handling

Storage

:

:

silver (Metallic)

ACGIH TLV (United States, 3/2012).
TWA: 0.1 mg/m³ 8 hours. Form: Dust and fumes
NIOSH REL (United States, 1/2013). Notes: as Ag
TWA: 0.01 mg/m³, (as Ag) 10 hours. Form: METAL DUST AND
SOLUBLE
OSHA PEL (United States, 6/2010). Notes: as Ag
TWA: 0.01 mg/m³, (as Ag) 8 hours.
OSHA PEL 1989 (United States, 3/1989). Notes: as Ag
TWA: 0.01 mg/m³, (as Ag) 8 hours.

2-methoxy-1-methylethyl acetate

AIHA WEEL (United States, 10/2011).
TWA: 50 ppm 8 hours.

n-butyl acetate

ACGIH TLV (United States, 3/2012).
STEL: 200 ppm 15 minutes.
TWA: 150 ppm 8 hours.
NIOSH REL (United States, 1/2013).
STEL: 950 mg/m³ 15 minutes.
STEL: 200 ppm 15 minutes.
TWA: 710 mg/m³ 10 hours.
TWA: 150 ppm 10 hours.
OSHA PEL (United States, 6/2010).
TWA: 710 mg/m³ 8 hours.
TWA: 150 ppm 8 hours.
OSHA PEL 1989 (United States, 3/1989).
STEL: 950 mg/m³ 15 minutes.
STEL: 200 ppm 15 minutes.
TWA: 710 mg/m³ 8 hours.
TWA: 150 ppm 8 hours.

butanone

ACGIH TLV (United States, 3/2012).
STEL: 885 mg/m³ 15 minutes.
STEL: 300 ppm 15 minutes.
TWA: 590 mg/m³ 8 hours.

8. Exposure controls/personal protection

Ingredient

Exposure limits

4/11

4011

6/27/2013.