Fuel information, A. fuel, B. gas pressure – Outdoor Great Room Intrigue Table Fire Pit User Manual
Page 8: C. gas connection

Page | 8
Intrigue 90215 REV E 6/7/2012
A. Fuel
Before making gas connections, ensure that
the appliance being installed is compatible
with the available gas type. This unit operates
on propane only.
B. Gas Pressure
Proper input pressures are required for
optimum appliance performance. Gas line
sizing requirements need to be made
following NFPA54
Pressure requirement for this
appliance:
Min- 11 in w.c.
Max- 14 in. w.c.
A preset non-adjustable tank regulator is supplied
3
Fuel Information
WARNING
Fire Risk
Explosion Risk
In the event of hard pipe
Installation,
Verify inlet pressures.
High pressure may cause overfire
condition.
Low pressure may cause explosion.
Verify minimum pressures when other
household gas appliances are
operating.
Install regulator upstream of valve if line
pressure is greater than ½ psig.
WARNING
Fire Risk
Explosion Risk
Verify inlet pressures.
Gas build-up during line purge may
ignite
Purge should be performed by a
qualified technician
Ensure adequate ventilation.
Ensure there are no ignition sources
such as sparks or open flame nearby.
When hard piped, the appliance and its individual
shutoff valve must be disconnected from the gas supply
piping system during any pressures in excess of ½ psi
(3.5 kPa) .
The appliance must be isolated from the gas supply
piping system by closing its individual manual shutoff
valve during any pressure testing of the gas supply
piping system at test pressures equal to or greater than
½ psi (3.5 kPa).
C. Gas Connection
Note: Have gas supply line installed in
accordance with local building codes, if any
exist. If not, follow ANSI 223.1. Installation
should be done by a qualified installer
approved and/or licensed as required by the
locality. (In the Commonwealth of
Massachusetts installation must be performed
by a licensed plumber or gas fitter.)
A small amount of air will be in the gas
supply lines. When first lighting the
appliance, it will take a short time for
air to purge from the lines. Subsequent
lighting of unit will not require such
purging.
WARNING
CHECK FOR GAS LEAKS
Fire Risk
Explosion Risk
Asphyxiation Risk
Check all fittings and connections.
Do not use open flame to check for leaks.
After the gas line installation is complete,
all connections must be tightened and
checked for leaks with a commercially
available, non-corrosive leak-check
solution. Be sure to rinse off all leak
check solution following testing.
Fittings and connections may have loosened
during shipping and handling.