Updx series – Bradford White UPDX2-75T6FRN User Manual
Page 6
Specifications
Thermal well ECO Limit
Residential 188°F (87°C), Commercial 199°F (93°C)
Residential Temperature
SetPoint Range
60°F (16°C) to 160°F (71°C) (Approximate temperatures)
Blower Temperature Switch
Normally closed, opens @ 155°F (68°C), auto reset @ 128°F (54°C).
Blower
115VAC, 60Hz, 3.1 amps.
Pressure switch
Standard Altitude-Normally open, closes at differential pressure of -.80.
High Altitude-Normally open, closes at differential pressure of -.73.
Power supply
Dedicated 115VAC, 60 Hz, 15A
Approved Gas Type
Natural. Unit must match gas type supplied.
Venting System
Power direct vent through the wall or vertical through the roof
Approved Vent Materials
PVC, CPVC or ABS
Gas Supply Pipe
Minimum 1/2" NPT (schedule 40 black iron pipe recommended)
Minimum Clearance
for Servicing
18" from top, 24" from front, 4" sides and rear.
Water Supply Pressure
150 PSI maximum allowable working pressure. Check local codes for supply pressure
Gas Pressure
6.0" W.C. min. for Nat gas, 11.0" W.C. min. for L.P. gas, 14.0" W.C. maximum (Nat. & L.P.)
Commercial Temperature
SetPoint Range
80°F (27°C) to 180°F (82°C) (Approximate temperatures)
Page 6
UPDX Series
6