beautypg.com

Updx series, Inner door removal procedure – Bradford White UPDX2-75T6FRN User Manual

Page 38

background image

Page 38

UPDX Series

Inner Door Removal Procedure

Step 1.

Position gas control power switch to the “OFF” position

Step 2.

Unplug the water heater from the wall outlet

Step 3.

Turn off the gas supply to the water heater

Step 4.

Remove the outer door.

Step 5.

Remove the four (4) ¼” hex drive screws holding the
right side inner door in place

Step 6.

Remove the three (3) ¼” hex drive screws
holding the left side burner door in place.

Step 7.

Disconnect the spark igniter wire and the
flammable vapor sensor harness from the gas
control.

Step 8.

Disconnect the pilot tube from the gas control using a
7/16" wrench. Remove the main burner feedline from
the gas control with a ¾” wrench.

Step 9.

Remove the burner assembly from the combustion chamber.

Step 10.

Fully inspect burner and inner door gaskets for the following:

>Tears

>Other imperfections that will inhibit proper seal

>Missing Material

>Gasket adhesion to inner door

>Cracks

>Material left on combustion chamber (around opening)

>Dirt or debris

If the gasket is not affected by any of the above, gasket replacement is not required. If replacement is
required, proceed to Inner Door Gasket Replacement Procedure.

¼” Hex Drive Screws Right

Side Inner Door

¼” Hex Drive Screws at Flange

Area of Inner Door

¼” Hex Drive Screws on Left Side

Inner Door

WARNING

If the information in these instructions is not

followed exactly, a fire or explosion may result causing

property damage, personal injury or death.

Gas Control shown in the “OFF” position

Flammable Vapor

Sensor Harness

Pilot Tube

Main Burner

Feedline

Spark Igniter Wire

UPDX SERVICE PROCEDURE XV

Inner Door/Gasket Removal, Inspection

Replacement and Reinstallation

38

This manual is related to the following products: