UPDX SERVICE PROCEDURE I

Burner Operation Inspection, Cleaning and

Replacement

Page 17

UPDX Series

Step 10.

Reassemble burner and reinstall into water heater. Restore gas supply and check for gas leaks.

Step 11.

To resume operation follow the instruction located on the lighting instruction label or the lighting
instruction located in the installation and operating manual.

Step 4.

Disconnect (unscrew) feedline from the main burner door.

Step 5.

Remove main burner orifice from feed line (3/8" wrench). Inspect and
clean if necessary

Step 6.

Remove pilot assembly, refer to UPDX SERVICE PROCEDURE II
for cleaning and inspection.

Step 7.

Reassemble burner.

Step 8.

Reinstall burner and inner door per UPDX SERVICE PROCEDURE XV,
steps 10 through 22.

Step 9.

To resume operation, follow the instructions located on the lighting instruction label or the lighting
instructions located in the installation and operation manual.

Feedline

Main Burner Orifice

Main Burner

Door

Burner Cleaning (Continued)

17