Flammable Vapor
Sensor

Step 1.

Position gas control power switch to
the “OFF” position.

Step 2.

Disconnect flammable vapor sensor
from gas control.

Step 3.

Using a multi-meter set to the ohms
setting check resistance of
flammable vapor sensor (see
caution below). Resistance must be
within 3,000 ohms and 48,000 ohms.
If outside of this range replace
flammable vapor sensor.

Flammable Vapor Sensor Testing

Flammable Vapor Sensor

Electronic
“pin type”
Meter Probes

Multi-meter set to
ohms setting

CAUTION

DO NOT use standard multimeter probes for this test. Doing

so will damage connector. Use special electronic “pin type”

probes or small diameter wire pins inserted into connector.

(The following chart is for models with serial numbers starting with “J” or earlier.)

Flammable

Vapor Sensor

Electronic
“pin type”
Meter Probes

CAUTION

DO NOT use standard multimeter probes for this test. Doing

so will damage connector. Use special electronic “pin type”

probes or small diameter wire pins inserted into connector.

Multi-meter set to
ohms setting

(The following chart is for models with serial numbers starting with “K” or later.)

Gas Control shown in the “OFF” Position

Resettable Thermal

Switch Wiring

UPDX SERVICE PROCEDURE IX

Flammable Vapor Sensor Testing