Burner cleaning, 7 burner cleaning – B&C Technologies IM Series Industrial Ironer User Manual
Page 69

Figure 5.17: Riello Cleaning diagram
3. Another normal path of failure of the mechanical seal is failure to observe the fill and vent
requirement for the main bearing bracket. If this operation is overlooked or not carried out
properly the seal will start up dry as will the main bearing and failure is only a matter of
time.
5.7.7
Burner Cleaning
To clean the blower cage on Riello Burners do the following:
1. Remove the damper servo gas control arm (B)from the gas butterfly cam by unscrewing the
standoff post.
2. Remove the damper servo mounting cradle (C) screws.
3. Remove the blower intake cover (A) shown in figure 5.17.
4. You should have access to the inside of the blower cage. It can be easily cleaned from the
inside with a shop-vac and a brush.
5. Reinstall the intake cover.
6. Reinstall the damper servo mounting cradle.
7. Reinstall the damper servo gas control arm, making sure it is mounted in the same hole you
removed it from.
59