Work rates, 1 roll 48"x118, 1 roll 48”x118 – B&C Technologies IM Series Industrial Ironer User Manual
Page 21: 3 work rates

sults will be obtained with a properly sized incoming gas line. Undersized gas lines will cause
performance and burner issues.
Table 3.1: IM Electrical & Gas Requirements
Model
BTU
Volts
FLA
Breaker
IM-12301-2T
800,000
200-230, 3ph, 50/60Hz
60
70
IM-12301-4T
800,000
380-460, 3ph, 50/60Hz
30
40
IM-12331-2T
800,000
200-230, 3ph, 50/60Hz
61
70
IM-12331-4T
800,000
380-460, 3ph, 50/60Hz
31
40
IM-12302-2T
1,600,000
200-230, 3ph, 50/60Hz
81
90
IM-12302-4T
1,600,000
380-460, 3ph, 50/60Hz
41
50
IM-12332-2T
1,600,000
200-230, 3ph, 50/60Hz
85
100
IM-12332-4T
1,600,000
380-460, 3ph, 50/60Hz
42
50
IM-8301-2T
600,000
200-230, 3ph, 50/60Hz
54
60
IM-8301-4T
600,000
440-460, 3ph, 50/60Hz
27
40
IM-8331-2T
600,000
200-230, 3ph, 50/60Hz
55
70
IM-8331-4T
600,000
440-460, 3ph, 50/60Hz
27
40
IM-8302-2T
1,200,000
200-230, 3ph, 50/60Hz
69
80
IM-8302-4T
1,200,000
440-460, 3ph, 50/60Hz
35
50
IM-8332-2T
1,200,000
200-230, 3ph, 50/60Hz
71
80
IM-8332-4T
1,200,000
440-460, 3ph, 50/60Hz
36
50
3.3
Work Rates
3.3.1
Realistic Work Rates for 1 Roll 48”x118” (1200mm) Ironer
Goods
Working Temperature
170C / 338F
180C / 356F
188C / 371F
200C / 390F
g/m2
lb/yd2
m/min
ft/min
kg/h
lb/hr
m/min
ft/min
kg/h
lb/hr
m/min
ft/min
kg/h
lb/hr
m/min
ft/min
kg/h
lb/hr
200
Sheets @ 80% Bed Coverage
130
0.2400
14
46
260
573
16
52
290
639
18
59
320
706
22
72
380
838
160
0.2954
11
36
260
573
13
43
290
639
15
49
320
706
19
62
380
838
190
0.3508
10
33
260
573
11
36
290
639
12
39
320
706
14
46
380
838
Small Pieces @ 60% Bed Coverage
220
0.4062
9
30
215
474
10.5
34
250
551
12
39
285
628
14
46
330
728
280
0.5170
7.5
25
225
496
9
30
270
595
10
33
300
662
11.5
38
345
761
330
0.6093
7
23
260
573
8
26
295
650
8.5
28
310
684
10
33
370
816
11