Dell PowerEdge 4350 User Manual

Page 33

Attention! The text in this document has been recognized automatically. To view the original document, you can use the "Original mode".

background image

Table

3

-

1

. Sysfem Messages

(continued)

Message

Cause

Corrective Action

Memory address

line failure at

address,

read

value

expecting

value

Memory double
word logic

failure at

address, read

value

expecting

value

Faulty or improperly

seated DIMM

Remove and reseat the
DIM Ms. If the problem per­

sists, replace the DIM Ms. See

"Adding Memory" in Chapters

for instructions on installing or

removing DIMMs. If the prob­
lem still persists, replace the
system board. See Chapter 12,

"Getting Help." for instruc­

tions on obtaining technical
assistance.

Memory odd/even

logic failure at

address,

read

value

expecting

value

Memory write/

read failure at
address, read

value

expecting

value

Memory alloca­

tion error

Faulty application

progam

Restart the application

program.

Memory parity

interrupt at

address

Faulty or improperly

seated DIMM

Remove and reseat the
DIMMs. If the problem per­

sists, replace the DIMMs. See

"Adding Memory" in Chapters

for instructions on installing or

removing DIMMs.

Memory tests

terminated by
keystroke

POST memory test ter­

minated by pressing the
spacebar

No action is required.

No boot device

available

Faulty diskette, diskette

drive subsystem, hard­
disk drive, hard-disk
drive subsystem, or no
boot disk in drive A

Replace the diskette or hard­

disk drive. If the problem
persists, replace the system
board. See Chapter 12. "Get­

ting Help," for instructions on

obtaining technical assistance.

NOTE: For the full name of an abbreviation or acronym used in this table, see the abbreviation and
acronym list that precedes the Index

Messages and Codes 3-5