Dell PowerEdge 4350 User Manual
Page 33
Attention! The text in this document has been recognized automatically. To view the original document, you can use the "Original mode".
Table
3
-
1
. Sysfem Messages
(continued)
Message
Cause
Corrective Action
Memory address
line failure at
address,
read
value
expecting
value
Memory double
word logic
failure at
address, read
value
expecting
value
Faulty or improperly
seated DIMM
Remove and reseat the
DIM Ms. If the problem per
sists, replace the DIM Ms. See
"Adding Memory" in Chapters
for instructions on installing or
removing DIMMs. If the prob
lem still persists, replace the
system board. See Chapter 12,
"Getting Help." for instruc
tions on obtaining technical
assistance.
Memory odd/even
logic failure at
address,
read
value
expecting
value
Memory write/
read failure at
address, read
value
expecting
value
Memory alloca
tion error
Faulty application
progam
Restart the application
program.
Memory parity
interrupt at
address
Faulty or improperly
seated DIMM
Remove and reseat the
DIMMs. If the problem per
sists, replace the DIMMs. See
"Adding Memory" in Chapters
for instructions on installing or
removing DIMMs.
Memory tests
terminated by
keystroke
POST memory test ter
minated by pressing the
spacebar
No action is required.
No boot device
available
Faulty diskette, diskette
drive subsystem, hard
disk drive, hard-disk
drive subsystem, or no
boot disk in drive A
Replace the diskette or hard
disk drive. If the problem
persists, replace the system
board. See Chapter 12. "Get
ting Help," for instructions on
obtaining technical assistance.
NOTE: For the full name of an abbreviation or acronym used in this table, see the abbreviation and
acronym list that precedes the Index
Messages and Codes 3-5