Dell PowerEdge 4350 User Manual
Page 30
Attention! The text in this document has been recognized automatically. To view the original document, you can use the "Original mode".

Table
3
-
1
. System Messages
Message
Cause
Corrective Action
Address mark
not found
Faulty diskette drive sub
system or hard-disk drive
subsystem (defective
system board)
Replace the system board.
See Chapter 12, "Getting
Help," for instructions on
obtaining technical assistance.
Alert!
Unbuffered and
registered
DIMMs cannot be
mixed
Combination of un
buffered and registered
DIMMs installed
Replace one or more DIMMs
so that all DIMMs are the
same type. See "Installing
DIMMs" and "Removing
DIMMs" in Chapter 8.
Attachment
failed to
respond
Diskette drive or hard
disk drive controller
cannot send data to
associated drive
Replace the drive's interface
cable.
Auxiliary
device failure
Loose or improperly con
nected mouse cable
connector or defective
mouse
Check the mouse cable
connection. If the problem
persists, replace the mouse.
Bad error-
correction
code{ECC) on
disk read
Faulty diskette sub
system or hard-disk drive
subsystem (defective
system board)
Replace the system board.
See Chapter 12, "Getting
Help," for instructions on
obtaining technical assistance.
Controller has
failed
Data error
Faulty diskette, diskette
drive, or hard-disk drive
Replace the diskette, diskette
drive, or hard-disk drive.
Decreasing
available
memory
Faulty or improperly
seated DIMMs
Remove and reseat the
DIMMs. See "Installing
DIMMs" and "Removing
DIMMs" in Chapters. If the
problem persists, replace the
DIMMs.
Diskette drive
0 seek failure
Diskette drive
1 seek failure
Faulty or improperly
inserted diskette,
incorrect configuration
settings in System Setup
program, loose diskette
drive interface cable, or
loose power cable
Replace the diskette. Run the
System Setup program to cor
rect the diskette drive type.
See Chapter 4, "Using the
System Setup Program," in
the system User's Guide for
instructions. Check the dis
kette drive-interface cable and
power cable connections to
the drive.
NOTE: For the full name of an abbreviation or acronym used in this table, see the abbreviation and
acronym list that precedes the Index
3-2 Dell PowerEdgei350 ^sterns Installation and Troubleshooting Guide