beautypg.com

Dell PowerEdge 4350 User Manual

Page 31

Attention! The text in this document has been recognized automatically. To view the original document, you can use the "Original mode".

background image

Table

3

-

1

. Sysfem Messages

(continued)

Message

Cause

Corrective Action

Diskette read

failure

Faulty diskette, faulty or

improperly connected
diskette drive interface
cable, or loose power
cable

Check the diskette drive inter­

face cable and power cable

connections to the drive. See
Chapter 9, "Installing the Dis­

kette and CD-ROM Drives."
Replace the diskette drive

interface cable.

Diskette sub­

system reset
failed

Faulty diskette drive con­

troller (defective system

board)

Replace the system board.

See Chapter 12, "Getting

Help," for instructions on

obtaining technical assistance.

Diskette write

protected

Diskette write-protect

feature activated

Move the write-protect tab on

the diskette.

Drive not ready

Diskette missing from or

improperly inserted in
diskette drive

Reinsert or replace the

diskette.

Embedded server

management

error

Embedded server

management is

not present

Embedded server man­

agement memory may

be temporarily corrupted

Shut down the system to clear

the memory, and then restart
the system. If the problem

persists, see Chapter 12,

"Getting Help," for instruc­

tions on obtaining technical
assistance.

Gate A20

failure

Faulty keyboard control­

ler (defective system
board)

Replace the system board.

See Chapter 12, "Getting

Help," for instructions on

obtaining technical assistance.

General failure

Operating system cor­
rupted or not installed
properly

Reinstall the operating

system.

Hard disk

controller

failure

Hard disk drive

read failure

Hard disk

failure

Incorrect configuration

settings in System Setup
program, improperly
connected hard-disk
drive, faulty hard-disk
drive controller
subsystem (defective
system board), or loose
power cable

Check the hard-disk drive
configuration settings in the
System Setup program. See
Chapter 4, "Using the System
Setup Program," in the
system User's Guide for
instructions. Reinstall the

hard-disk drive. Check the

interface cable and power
cable connections to the back­
plane board. See Chapter 10,

"Installing Hard-Disk Drives."

NOTE: For the full name of an abbreviation or acronym used in this table, see the abbreviation and
acronym list that precedes the Index

Messages and Codes 3-3