Humidity too high when the unit is not running

Possible Cause

Solution

Unit needs to run to dehumidify

Run unit. Seal openings around doors (gasket and

sweep)

Humidity too high when unit is running and cooling

Possible Cause

Solution

Too much moisture in cellar Poor vapor barrier installation

Humidifier malfunction refer to
the humidifier instructions.

Add dehumidifier to surrounding space

Other Miscellaneous Problems

Unit operates but the power switch light is not ON


Possible Cause

Solution

Bulb is burned out

Replace bulb

Unit is leaking water

Possible Cause

Solution

Piping from unit to drain is trapped Re-pipe to remove external traps

Trap plugged Clean trap

Condensate pan plugged

Remove blockage and clean

Unit not level

Level with shims

Unit is running properly, but the sound of the unit is objectionable

Possible Cause

Solution

Noise is from airflow Redirect airflow
Add baffles

Add insulated ductwork

Noise is from unit

Add sound baffle between unit and occupied

space