beautypg.com

Installing the ductwork, Location of supply and return grilles – Wine Guardian Wine Cellar Cooling Systems 50Hz (WG 175) User Manual

Page 38

background image

Installing the Ductwork

Use ductwork to connect the unit to the supply and return outlets in the wine cellar. Use only insulated
ductwork to minimize cooling loses, prevent sweating, and to reduce noise.

Use ductwork on the condenser section to redirect or absorb sound, to bring in outside air to the unit
inlet, and/or to exhaust the hot air out of the ambient space.

NOTE

Do not exceed a total of 7.5 meters for each length of ductwork run.

Model

Inlet

Outlet

Single

Double

WG40

200

200

200

150

WG75

250

200

250

150

WG100

250

250

250

200

WG175

300

300

300

300

Condenser (heat rejection) Coil

Recommended Insulated Flexible ductwork Sizing Chart

Inlet (Return Air)

Outlet (supply air)

Single

200
250

Double

150
150
200
250

250
300

Evaporator (cooling) Coil

Notes: 1. The above references izes are internal diameter in mm.
2. If a single supply is used out of the unit but then splits into two (2) ducts, the above size
recommended for double is used after the split.

CAUTION

RISK OF DAMAGE TO EQUIPMENT

Avoid crimping the flexible ducts. This chokes down the inside area and reduces the airflow

causing the unit to operate erratically.

Be sure all ducts and surface in contact with the airflow are insulated

and have a vapor barrier on the outside surface.

Location of Supply and Return Grilles

Locate the supply and return grilles inside the cellar to create an airflow pattern that maximizes
air circulation in the room. Avoid short circulating of the air.

Do Not:

Install the return air grilles directly on the floor as the grilles will collect dust from the

floor.

Locate the supply or return air grille where it is blocked by bottles, boxes or cases.

Locate the supply air grille where it blows directly on the thermostat.

Relocating a grille on the Wine Guardian

1) Remove the fasteners from the grille.
2) Remove the fasteners from the access door panel to be replaced by the grille.
3) Relocate the outlet grille to its new location and secure in place using its fasteners.
4) Replace the access door panel where grille was located.

35