Wiring the Unit for Power

DANGER

ELECTRICAL SHOCK HAZARD

RISK OF SERIOUS INJURY OR DEATH

The electrical outlet and wiring installation must meet the national and local

building codes.

DO:

 Match the electrical outlet to the plug provided on the Wine Guardian.

 Provide dedicated circuit and wiring for the system.

 Match the wiring and breaker size to the rated load as shown on the serial

plate and in this guide. See sample serial plate illustration on the following page.





DO NOT:

 DO NOT MODIFY THE PLUGS IN ANY WAY!

 Do not use extension cords.


24

23

Electrical

240/1/50

Electric Heat Amps (Opt.)

4.4

Locked Rotor Amps

18.5

Humidifier Amps (opt.)

0.3

Compressor RLA

2.4

Crankcase Htr. Amps (opt.)

0.4

Condenser Fan Amps

0.7

Min. Circuit Amps (w/o opt.)

4.4

Evaporator Fan Amps

0.7

Refrigerant

R-134-A

Condensate Heater

N/A

System Charge

1lb. 3oz.

Total Unit Amps (w/o opt.)

3.8

Test Pressure

275psi