Wiring the Unit for Power
DANGER
ELECTRICAL SHOCK HAZARD
RISK OF SERIOUS INJURY OR DEATH
The electrical outlet and wiring installation must meet the national and local
building codes.
DO:
Match the electrical outlet to the plug provided on the Wine Guardian.
Provide dedicated circuit and wiring for the system.
Match the wiring and breaker size to the rated load as shown on the serial
plate and in this guide. See sample serial plate illustration on the following page.
DO NOT:
DO NOT MODIFY THE PLUGS IN ANY WAY!
Do not use extension cords.
24
23
Electrical
240/1/50
Electric Heat Amps (Opt.)
4.4
Locked Rotor Amps
18.5
Humidifier Amps (opt.)
0.3
Compressor RLA
2.4
Crankcase Htr. Amps (opt.)
0.4
Condenser Fan Amps
0.7
Min. Circuit Amps (w/o opt.)
4.4
Evaporator Fan Amps
0.7
Refrigerant
R-134-A
Condensate Heater
N/A
System Charge
1lb. 3oz.
Total Unit Amps (w/o opt.)
3.8
Test Pressure
275psi
00 1 315-452-7400 * Fax: 00 1 315-452-7420
Model No. WG40
Serial No.
Air Innovations, 7000 Performance Drive, North Syracuse, New York 13212