Troubleshooting, Important, Typical start-up problems – Wine Guardian Wine Cellar Cooling Systems 50Hz (WG 175) User Manual

Page 48: Unit does not start-up

background image

Troubleshooting

WARNING

BEFORE PROCEEDING, READ AND UNDERSTAND THE SAFETY INFORMATION CONTAINED IN

THE SAFETY SECTION OF THE WINE GUARDIAN MANUAL.

IMPORTANT

This section is intended as a diagnostic aid only. For detailed repair or parts replacement

procedures, contact a qualified service company. Check the following table for some solutions

before calling a service technician.

Typical Start-up Problems

Possible Cause

Loose, improper or defective
thermostat or humidistat cable

Solution

Check power, and thermostat
or humidistat cable

Incorrect thermostat or
humidistat (optional) settings.

Check the thermostat and optional
humidistat setup for the application.

Changed settings on the thermostat

A common problem is not waiting long
enough for the internal timers to complete
their timed delay.

Unit Does Not Start-up

Power Switch Light is Off

Possible Cause Solution
Switch not on Turn on switch
No power to outlet Check circuit breaker and wiring
Unit not plugged in Plug in the unit

Power Switch Light is On and the Thermostat Light is Off

Possible Cause Solution

No power to thermostat Check Main Control Board for L.E.D.

indication
Check wiring for loose, broken or frayed

connections
Check wiring for proper splicing

Remote Interface Controller may be faulty

Power Switch Light is On and the Thermostat Light is On

Possible Cause Solution

Thermostat is not set up properly Check thermostat set up in the guide.
Press fan ON switch to check evaporator
fan only

45